Building Science Experts' Session

Nov
20
2019

Westford, MA

Nov
21
2019

Westford, MA

The Building Science Experts' Session is held over two days. Each day begins at 8:30 am and runs through 5:00 pm. There is a separate topic and separate registration for each day as noted below. Each day is $495 to attend. To register for both days, select the first day, click Register, click Continue Shopping, then select the second day.

The fee includes breakfast and lunch but does not include travel or accommodations. There is a 5% cancellation fee that we apply to refunds by credit card.

 Hotel details

LocationHotelAddressPhoneRooms
Westford, MA
Westford Regency Inn and Conference Center219 Littleton Road Westford, MA
978-692-8200Guest rooms are available at the location of the seminar for the cost of $132.00

Agenda: 

Day One

High Performance Walls

A technical look at all of the combinations and permutations of walls - commercial, institutional and residential. Frame walls, mass walls. Brick, stone, stucco, wood cladding, composite cladding, metal cladding, fiber cement siding, engineered wood siding, vinyl siding, aluminum siding, curtain walls storefronts. Building papers, plastic building wraps and house wraps, fully adhered membranes that are vapor open and vapor closed and vapor in between, liquid applied, spray applied water resistant barriers. Gypsum sheathing, oriented strand board sheathing, plywood sheathing, fiberboard sheathing, board sheathing. Steel studs, wood studs, precast, block back up walls. Fiberglass cavity insulation, cellulose cavity insulation, low density spray foam, high density spray foam. Gypsum interior linings, magnesium oxide boards, lath and plaster. Latex paints, alkyd paints and epoxy paints. Continuous insulations rock wool, extruded polystyrene, expanded polystyrene, isocyanurates and insulated metal panels. How all of these assemblies work in all the climate zones?

Day Two

High Performance Roofs

A technical look at all of the combinations and permutations of roofs - commercial, institutional and residential. Vented and unvented. Metal decks, wood decks, concrete decks. Wood trusses, metal trusses, rafter construction. Rigid insulation boards, spray foams, fiberglass, cellulose, rock wool. Single ply membranes, asphalt shingles, wood shingles, wood shakes, slate, metal, insulated metal panels, clay tile, concrete tile. Green roofs, protected membrane roofs, plaza decks, balconies. Hot fluid applied waterproofing, cold fluid applied waterproofing. Wild fire, hurricane and ice dam resistance. How all of these assemblies work in all the climate zones. We now have vapor diffusion venting rather than air flow venting. We have problems with open cell low density spray foam that we didn’t have back in the day….Spend a day with Dr. Joe as he goes through the history of roof venting bringing you up to speed on the problems in high performance roofs in cold climates and high performance roofs in hot climates. How to avoid the problems and how to fix them and how we got em...

Continuing Education: 

American Institute of Architects (AIA)
8 LU|HSW

Speakers: