Fill in the search criteria to search the database or view index of all documents.

climates

Very Cold - A very cold climate is defined as a region with approximately 9,000 heating degree days or greater (65°F basis) or greater and less than 12,600 heating degree days (65°F basis).

Cold - A cold climate is defined as a region with approximately 5,400 heating degree days (65°F basis) or greater and less than approximately 9,000 heating degree days (65°F basis).

Mixed-Humid - A mixed-humid and warm-humid climate is defined as a region that receives more than 20 inches of annual precipitation with approximately 4,500 cooling degree days (50°F basis) or greater and less than approximately 6,300 cooling degree days (50°F basis) and less than approximately 5,400 heating degree days (65°F basis) and where the average monthly outdoor temperature drops below 45°F during the winter months.

Hot-Humid - A hot-humid climate is defined as a region that receives more than 20 inches of annual precipitation with approximately 6,300 cooling degree days (50°F basis) or greater and where the monthly average outdoor temperature remains above 45°F throughout the year. This definition characterizes a region that is similar to the ASHRAE definition of hot-humid climates where one or both of the following occur:

  • a 67°F r higher wet bulb temperature for 3,000 or more hours during the warmest six consecutive months of the year; or
  • a 73°F or higher wet bulb temperature for 1,500 or more hours during the warmest six consecutive months of the year.

Hot-Dry/Mixed-Dry - A hot-dry climate is defined as region that receives less than 20 inches of annual precipitation with approximately 6,300 cooling degree days (50°F basis)or greater and where the monthly average outdoor temperature remains above 45°F throughout the year.

A warm-dry and mixed-dry climate is defined as a region that receives less than 20 inches of annual precipitation with approximately 4,500 cooling degree days (50°F basis) or greater and less than approximately 6,300 cooling degree days (50°F basis) and less than approximately 5,400 heating degree days (65°F basis) and where the average monthly outdoor temperature drops below 45°F during the winter months.

Marine - A marine climate meets is defined as a region where all of the following occur:

  • a mean temperature of the coldest month between 27°F and 65°F;
  • a mean temperature of the warmest month below 72°F;
  • at least four months with mean temperatures over 50°F; and
  • a dry season in the summer, the month with the heaviest precipitation in the cold season has at least three times as much precipitation as the month with the least precipitation.

information

Building Science Insights are short discussions on a particular topic of general interest. They are intended to highlight one or more building science principles. The discussion is informal and sometimes irreverent but never irrelevant.

Building Science Digests provide building professionals from different disciplinary backgrounds with concise overview of important building science topics. Digests explain the theory behind each topic and then translate this theory into practical information.

Published Articles aare a selected set of articles written by BSC personnel and published in professional and trade magazines that address building science topics. For example, our work has appeared in Fine Homebuilding, Home Energy, ASHRAE's High Performance Buildings, The Journal of Building Enclosure Design and The Journal of Building Physics. We thank these publications for their gracious permission to republish.

Conference Papers are peer-reviewed papers published in conference proceedings.

Research Reports are technical reports written for researchers but accessible to design professionals and builders. These reports typically provide an in-depth study of a particular topic or describe the results of a research project. They are often peer reviewed and also provide support for advice given in our Building Science Digests.

Building America Reports are technical reports funded by the U.S. Department of Energy (DOE) Building America research program.

Designs That Work are residential Case Studies and House Plans developed by BSC to be appropriate for residential construction in specific climate zones. Case Studies provide a summary of results for homes built in partnership with BSC’s Building America team. The case study typically includes enclosure and mechanical details, testing performed, builder profile, and unique project highlights. House Plans are fully integrated construction drawing sets that include floor plans, framing plans and wall framing elevations, exterior elevations, building and wall sections, and mechanical and electrical plans.

Enclosures That Work are Building Profiles and High R-Value Assemblies developed by BSC to be appropriate for residential construction in specific climate zones. Building Profiles are residential building cross sections that include enclosure and mechanical design recommendations. Most profiles also include field expertise notes, material compatibility analysis, and climate challenges. High R-Value Assemblies are summaries of the results of BSC's ongoing High R-Value Enclosure research — a study that BSC has undertaken for the U.S. Department of Energy (DOE) Building America research program to identify and evaluate residential assemblies that cost-effectively provide 50 percent improvement in thermal resistance.

Guides and Manuals are "how-to" documents, giving advice and instructions on specific building techniques and methods. Longer guides and manuals include background information to help facilitate a strong understanding of the building science behind the hands-on advice. This section also contains two quick, easy-to-read series. The IRC FAQ series answers common questions about the building science approach to specific building tasks (for example, insulating a basement). The READ THIS: Before... series offers guidelines and recommendations for everyday situations such as moving into a new home or deciding to renovate.

Information Sheets are short, descriptive overviews of basic building science topics and are useful both as an introduction to building science and as a handy reference that can be easily printed for use in the field, in a design meeting, or at the building permit counter. Through illustrations, photographs, and straightforward explanations, each Information Sheet covers the essential aspects of a single topic. Common, avoidable mistakes are also examined in the What's Wrong with this Project? and What's Wrong with this Practice? mini-series.

Videos.

Guides and Manuals
Building Science Corporation

This guide details the interior vapor retarder requirements as per building code when insulating sheathing is installed on the outside of an exterior wall. The interior vapor retrader can be removed in certain cases and the underlying physics is...
Guides and Manuals
Building Science Corporation

This guide details wall bracing requirements for insulating sheathing as per building code and clarifies whether insulation board can be installed in lieu of plywood on the outside on an exterior wall.Q. Can I install insulation board, in lieu of...
Guides and Manuals
Building Science Corporation

This guide provides code requirements for basement insulation and clarifies whether building code allows for leaving insulation exposed in the basement. The requirements are based on whether the basement is conditioned or not and whether the...
Guides and Manuals
Building Science Corporation

This appendix contains Building Science Information Sheets that provide more information for specific inspection points on the BSC Building America Quality Control Checklist. Each Information Sheet is a one or two page document that can easily be...
Guides and Manuals
Building Science Corporation

The Building America Quality Control Checklist has been developed by Building Science Corporation as both a guide to assist in the transition to high performance home building, and as a simplified tool to be used as part of any builder's on-site...
Guides and Manuals
Alex Lukachko

BSC’s Quality Assurance Roadmap outlines the approach to quality assurance in the construction process as recommended by Building Science Corporation for new residential construction. Seven process steps are described from the assessment of current...
Guides and Manuals
Peter Baker

Residential housing design continues to move towards the development of high performance sustainable building systems. To be sustainable, a building must not only be efficient and durable but also economically viable. From this, new methods of...
Guides and Manuals
Building Science Corporation

Water management is based on the basic principles of physics. The concepts of drainage, wetting and drying potential are generally easy to understand. Explaining with graphics, text, or words what needs to be done for proper water management can be...
Guides and Manuals
Joseph Lstiburek

How you live in your home and how you clean and maintain your home affect the quality of air in your home. Keeping your home clean and dry makes it comfortable and healthy for you and unfriendly and unwelcoming to pests.The Building...
Guides and Manuals
Armin Rudd

A design process is described for sizing cooling and heating system capacity, for specifying the airflow and duct sizes to each conditioned space, and for specifying the free area needed to transfer air supplied to closed rooms back to the central...
Guides and Manuals
Armin Rudd

This document reviews ventilation strategies for different climate zones and includes schematic drawings and photographs of various ventilation installations. It provides practical recommendations for meeting ventilation requirements of healthy and...
Guides and Manuals
Joseph Lstiburek

This pamphlet is designed for members of the residential construction and remodeling industries, as well as owners and managers who work in affordable housing. It presents building guidance for both new construction and rehabilitation, as well as...
Guides and Manuals
Joseph Lstiburek

This pamphlet is designed for members of the residential construction and remodeling industries, as well as owners and managers who work in affordable housing. It presents building guidance for both new construction and rehabilitation, as well as...
Guides and Manuals
Building Science Corporation

After a high performance home has been designed, constructed, and commissioned, what ensures that the home is actually operated at peak performance? It takes just 24 easy-reading pages for the homeowner to learn just how simple it is to achieve the...
Cold
Guides and Manuals
Armin Rudd

This guide reviews current and potential ventilation technologies for residential buildings with particular emphasis on North American climates and construction. The major technologies reviewed include a variety of mechanical systems, natural...
Guides and Manuals
Joseph Lstiburek

This guide reviews the performance of residential assemblies in the central Florida (Orlando) area during the three hurricanes in August and September 2004. The specific focus of the review is on the water management details associated with stucco ...
Hot-Humid

Freeze-Thaw Risk: Site Visit Back to Recommended Freeze-Thaw Risk Assessment Steps Inspection by a building scientist can often identify existing moisture problems (due to rainwater, rising damp, air leakage, etc.) that must be addressed before...

Freeze-Thaw Risk: Site Load AssessmentBack to Recommended Freeze-Thaw Risk Assessment StepsMost of the moisture that masonry walls must deal with comes from wind-driven rain. Unfortunately, the amount of driving rain that a given wall will encounter...

Freeze-Thaw Risk: Repair/Retrofit, Maintain and Monitor Back to Recommended Freeze-Thaw Risk Assessment Steps Each retrofit project is unique: the building’s features and historical significance, the site conditions, and the time and money...

Freeze-Thaw Risk: Prototype Monitoring Back to Recommended Freeze-Thaw Risk Assessment Steps In some cases, the risk of adding interior insulation is still not clear enough even after materials testing and site load monitoring. In these...

Pages