Very Cold - A very cold climate is defined as a region with approximately 9,000 heating degree days or greater (65°F basis) or greater and less than 12,600 heating degree days (65°F basis).
Cold - A cold climate is defined as a region with approximately 5,400 heating degree days (65°F basis) or greater and less than approximately 9,000 heating degree days (65°F basis).
Mixed-Humid - A mixed-humid and warm-humid climate is defined as a region that receives more than 20 inches of annual precipitation with approximately 4,500 cooling degree days (50°F basis) or greater and less than approximately 6,300 cooling degree days (50°F basis) and less than approximately 5,400 heating degree days (65°F basis) and where the average monthly outdoor temperature drops below 45°F during the winter months.
Hot-Humid - A hot-humid climate is defined as a region that receives more than 20 inches of annual precipitation with approximately 6,300 cooling degree days (50°F basis) or greater and where the monthly average outdoor temperature remains above 45°F throughout the year. This definition characterizes a region that is similar to the ASHRAE definition of hot-humid climates where one or both of the following occur:
- a 67°F r higher wet bulb temperature for 3,000 or more hours during the warmest six consecutive months of the year; or
- a 73°F or higher wet bulb temperature for 1,500 or more hours during the warmest six consecutive months of the year.
Hot-Dry/Mixed-Dry - A hot-dry climate is defined as region that receives less than 20 inches of annual precipitation with approximately 6,300 cooling degree days (50°F basis)or greater and where the monthly average outdoor temperature remains above 45°F throughout the year.
A warm-dry and mixed-dry climate is defined as a region that receives less than 20 inches of annual precipitation with approximately 4,500 cooling degree days (50°F basis) or greater and less than approximately 6,300 cooling degree days (50°F basis) and less than approximately 5,400 heating degree days (65°F basis) and where the average monthly outdoor temperature drops below 45°F during the winter months.
Marine - A marine climate meets is defined as a region where all of the following occur:
- a mean temperature of the coldest month between 27°F and 65°F;
- a mean temperature of the warmest month below 72°F;
- at least four months with mean temperatures over 50°F; and
- a dry season in the summer, the month with the heaviest precipitation in the cold season has at least three times as much precipitation as the month with the least precipitation.
Building Science Insights are short discussions on a particular topic of general interest. They are intended to highlight one or more building science principles. The discussion is informal and sometimes irreverent but never irrelevant.
Building Science Digests provide building professionals from different disciplinary backgrounds with concise overview of important building science topics. Digests explain the theory behind each topic and then translate this theory into practical information.
Published Articles aare a selected set of articles written by BSC personnel and published in professional and trade magazines that address building science topics. For example, our work has appeared in Fine Homebuilding, Home Energy, ASHRAE's High Performance Buildings, The Journal of Building Enclosure Design and The Journal of Building Physics. We thank these publications for their gracious permission to republish.
Conference Papers are peer-reviewed papers published in conference proceedings.
Research Reports are technical reports written for researchers but accessible to design professionals and builders. These reports typically provide an in-depth study of a particular topic or describe the results of a research project. They are often peer reviewed and also provide support for advice given in our Building Science Digests.
Building America Reports are technical reports funded by the U.S. Department of Energy (DOE) Building America research program.
Designs That Work are residential Case Studies and House Plans developed by BSC to be appropriate for residential construction in specific climate zones. Case Studies provide a summary of results for homes built in partnership with BSC’s Building America team. The case study typically includes enclosure and mechanical details, testing performed, builder profile, and unique project highlights. House Plans are fully integrated construction drawing sets that include floor plans, framing plans and wall framing elevations, exterior elevations, building and wall sections, and mechanical and electrical plans.
Enclosures That Work are Building Profiles and High R-Value Assemblies developed by BSC to be appropriate for residential construction in specific climate zones. Building Profiles are residential building cross sections that include enclosure and mechanical design recommendations. Most profiles also include field expertise notes, material compatibility analysis, and climate challenges. High R-Value Assemblies are summaries of the results of BSC's ongoing High R-Value Enclosure research — a study that BSC has undertaken for the U.S. Department of Energy (DOE) Building America research program to identify and evaluate residential assemblies that cost-effectively provide 50 percent improvement in thermal resistance.
Guides and Manuals are "how-to" documents, giving advice and instructions on specific building techniques and methods. Longer guides and manuals include background information to help facilitate a strong understanding of the building science behind the hands-on advice. This section also contains two quick, easy-to-read series. The IRC FAQ series answers common questions about the building science approach to specific building tasks (for example, insulating a basement). The READ THIS: Before... series offers guidelines and recommendations for everyday situations such as moving into a new home or deciding to renovate.
Information Sheets are short, descriptive overviews of basic building science topics and are useful both as an introduction to building science and as a handy reference that can be easily printed for use in the field, in a design meeting, or at the building permit counter. Through illustrations, photographs, and straightforward explanations, each Information Sheet covers the essential aspects of a single topic. Common, avoidable mistakes are also examined in the What's Wrong with this Project? and What's Wrong with this Practice? mini-series.
Videos.
Designs that Work
This Cape Cod style house was built in 1953. While the owners had made interior improvements and necessary repairs in the 25 years since they purchased the house, they now wanted to do some exterior upgrades and at the same time tighten up the house...
Cold
Designs that Work
BSC collaborated with Greencraft Builders in Lewisville, TX on a 2009 prototype house called the TimberCreek Net Zero Energy House. This house demonstrates the energy efficiency and durability upgrades that Greencraft has been promoting for years....
Mixed-Humid
Designs that Work
Habitat for Humanity North Central Massachusetts received this circa 1900 property as a donation from the Town of Lancaster. The building had been in a state of significant deterioration, yet preserving the footprint and first floor framing was...
Cold
Designs that Work
The Lake Charles, LA house is a 1,255 square foot, one-and-a-half story single-family detached house with three bedrooms, two baths, raised on a pier foundation located in Lake Charles, LA (Hot-Humid Climate). It features an unvented roof with 2...
Hot-Humid
Designs that Work
In the first part of the text, which describes the Basic Hot-Humid Climate House, you will find a step-by-step explanation of how we applied climate-specific design and building science principles. The second section describes advanced technology...
Hot-Humid
Designs that Work
The Juneau, AK house is a 1,190 square foot, one-and-a-half story single-family detached house with three bedrooms, two baths, built on piers located in Juneau, AK (Very Cold Climate). It features a vented roof with 2 layers of 6” EPS rigid...
Very Cold
Designs that Work
In the first part of the text, which describes the Basic Very Cold Climate House, you will find a step-by-step explanation of how we applied climate-specific design and building science principles. The second section describes advanced technology...
Very Cold
Designs that Work
This triple decker, built in 1907, was purchased in 2006 by the current owner who occupies one of the units along with her husband and their toddler. As an initial step towards improving the energy efficiency and combustion safety of the building,...
Cold
Designs that Work
This project includes two David Weekley Homes developments near Houston, Texas: Eagle Springs and Waterhaven. These two developments are located in Humble and Atascocita, Texas and consist of one- or two-story single-family houses between 1800 and...
Hot-Humid
Designs that Work
Primarily as a resort location, Hilton Head Island has a somewhat different residential housing market than other more traditional areas. The market is made up of both year-round occupancy and seasonal occupancy, and the size and cost of new homes...
Hot-Humid
Designs that Work
The Haymount, VA house is a 1,260 square foot, one-and-a-half story single-family detached house with three bedrooms, two baths, and an 816 square foot crawlspace located in Haymount, VA (Mixed-Humid Climate). It features a vented roof with 2” air...
Mixed-Humid
Designs that Work
In the first part of the text, which describes the Basic Mixed-Humid Climate House, you will find a step-by-step explanation of how we applied climate-specific design and building science principles. The second section describes advanced technology...
Mixed-Humid
Designs that Work
The Greensburg, KS house is a 1,350 square foot, one-and-a-half story single-family detached house with three bedrooms, two baths, and an 816 square foot basement located in Greensburg, KS (Mixed-Humid Climate). It features a vented roof with 2” air...
Mixed-Humid
Designs that Work
Every home built by Prairie Holdings Corporation has a controlled ventilation system that enhances indoor air quality and comfort by bringing in outside air when needed by the occupants. Typical homes have no way of providing outdoor air in a...
Cold
Designs that Work
Take a look at the Prairie Crossing homes—they are "Heartland" homes that anyone would love to live in, reassuringly traditional. Who would think that they also happen to be among the most sophisticated and finely tuned high performance homes in...
Cold
Designs that Work
In 1920, when this house was built on the bank of a coastal cove, it served as a summer cottage complete with a boat dock. Over the years, the house has been remodeled, added to, and converted to a year-round residence. Now, as part of the latest...
Cold
Designs that Work
Baxter Village is a residential community located approximately 20 miles south of Charlotte, North Carolina. The development is being constructed by the Charlotte division of David Weekley Homes (DWH). Baxter Village in Fort Mill, South Carolina is...
Mixed-Humid
Designs that Work
Hamilton Way is a ten-lot subdivision located just outside of Hartford in Farmington, Connecticut. It is a community designed and constructed through a partnership between Landworks Realty and Nelson Construction. Building Science Corporation (BSC)...
Cold
Designs that Work
Sandstone is a 49-home subdivision located in Ellendale, DE. The project is Colter Construction’s first entry into community-scale development. The homes are intended to be attractive to the first-time homeowner, and to empty nesters, two strong...
Mixed-Humid
Designs that Work
The Denver, CO house is a two story, four bedroom, one-and-a-half bath single-family house with a conditioned crawlspace designed for Habitat for Humanity of Metro Denver located in Denver, CO (Cold Climate). It features a vented attic with R-38...
Cold