- Our Services
- Articles and Papers
- Guidance
- Popular Topics
- Bookstore
- Events and Training
Document Search
Fill in the search criteria to search the database or view index of all documents.

Very Cold - A very cold climate is defined as a region with approximately 9,000 heating degree days or greater (65°F basis) or greater and less than 12,600 heating degree days (65°F basis).
Cold - A cold climate is defined as a region with approximately 5,400 heating degree days (65°F basis) or greater and less than approximately 9,000 heating degree days (65°F basis).
Mixed-Humid - A mixed-humid and warm-humid climate is defined as a region that receives more than 20 inches of annual precipitation with approximately 4,500 cooling degree days (50°F basis) or greater and less than approximately 6,300 cooling degree days (50°F basis) and less than approximately 5,400 heating degree days (65°F basis) and where the average monthly outdoor temperature drops below 45°F during the winter months.
Hot-Humid - A hot-humid climate is defined as a region that receives more than 20 inches of annual precipitation with approximately 6,300 cooling degree days (50°F basis) or greater and where the monthly average outdoor temperature remains above 45°F throughout the year. This definition characterizes a region that is similar to the ASHRAE definition of hot-humid climates where one or both of the following occur:
- a 67°F r higher wet bulb temperature for 3,000 or more hours during the warmest six consecutive months of the year; or
- a 73°F or higher wet bulb temperature for 1,500 or more hours during the warmest six consecutive months of the year.
Hot-Dry/Mixed-Dry - A hot-dry climate is defined as region that receives less than 20 inches of annual precipitation with approximately 6,300 cooling degree days (50°F basis)or greater and where the monthly average outdoor temperature remains above 45°F throughout the year.
A warm-dry and mixed-dry climate is defined as a region that receives less than 20 inches of annual precipitation with approximately 4,500 cooling degree days (50°F basis) or greater and less than approximately 6,300 cooling degree days (50°F basis) and less than approximately 5,400 heating degree days (65°F basis) and where the average monthly outdoor temperature drops below 45°F during the winter months.
Marine - A marine climate meets is defined as a region where all of the following occur:
- a mean temperature of the coldest month between 27°F and 65°F;
- a mean temperature of the warmest month below 72°F;
- at least four months with mean temperatures over 50°F; and
- a dry season in the summer, the month with the heaviest precipitation in the cold season has at least three times as much precipitation as the month with the least precipitation.
Building Science Insights are short discussions on a particular topic of general interest. They are intended to highlight one or more building science principles. The discussion is informal and sometimes irreverent but never irrelevant.
Building Science Digests provide building professionals from different disciplinary backgrounds with concise overview of important building science topics. Digests explain the theory behind each topic and then translate this theory into practical information.
Published Articles aare a selected set of articles written by BSC personnel and published in professional and trade magazines that address building science topics. For example, our work has appeared in Fine Homebuilding, Home Energy, ASHRAE's High Performance Buildings, The Journal of Building Enclosure Design and The Journal of Building Physics. We thank these publications for their gracious permission to republish.
Conference Papers are peer-reviewed papers published in conference proceedings.
Research Reports are technical reports written for researchers but accessible to design professionals and builders. These reports typically provide an in-depth study of a particular topic or describe the results of a research project. They are often peer reviewed and also provide support for advice given in our Building Science Digests.
Building America Reports are technical reports funded by the U.S. Department of Energy (DOE) Building America research program.
Designs That Work are residential Case Studies and House Plans developed by BSC to be appropriate for residential construction in specific climate zones. Case Studies provide a summary of results for homes built in partnership with BSC’s Building America team. The case study typically includes enclosure and mechanical details, testing performed, builder profile, and unique project highlights. House Plans are fully integrated construction drawing sets that include floor plans, framing plans and wall framing elevations, exterior elevations, building and wall sections, and mechanical and electrical plans.
Enclosures That Work are Building Profiles and High R-Value Assemblies developed by BSC to be appropriate for residential construction in specific climate zones. Building Profiles are residential building cross sections that include enclosure and mechanical design recommendations. Most profiles also include field expertise notes, material compatibility analysis, and climate challenges. High R-Value Assemblies are summaries of the results of BSC's ongoing High R-Value Enclosure research — a study that BSC has undertaken for the U.S. Department of Energy (DOE) Building America research program to identify and evaluate residential assemblies that cost-effectively provide 50 percent improvement in thermal resistance.
Guides and Manuals are "how-to" documents, giving advice and instructions on specific building techniques and methods. Longer guides and manuals include background information to help facilitate a strong understanding of the building science behind the hands-on advice. This section also contains two quick, easy-to-read series. The IRC FAQ series answers common questions about the building science approach to specific building tasks (for example, insulating a basement). The READ THIS: Before... series offers guidelines and recommendations for everyday situations such as moving into a new home or deciding to renovate.
Information Sheets are short, descriptive overviews of basic building science topics and are useful both as an introduction to building science and as a handy reference that can be easily printed for use in the field, in a design meeting, or at the building permit counter. Through illustrations, photographs, and straightforward explanations, each Information Sheet covers the essential aspects of a single topic. Common, avoidable mistakes are also examined in the What's Wrong with this Project? and What's Wrong with this Practice? mini-series.
Videos.
Building America Reports
Building Science Corporation
PV systems have come a long way in the last two decades. While they may not work for all homes, residential installations are becoming a practical reality under more and more conditions. Here are the nitty-gritty details of photovoltaic systems. The details are meant to “de-mystify” both the technology and its economics.
Building America Reports
Building Science Corporation
Heat loss from basements accounts for a significant portion of the energy loss from a home. In many jurisdictions, basement insulation is a building code requirement. Cost usually determines the type of insulation system used. Unfortunately, safely insulating basement walls requires consideration of many factors in addition to reducing thermal conductivity across the foundation wall. Moisture dynamics must be considered in detail before insulating a basement wall. Materials used to insulate a basement wall must be selected based on their ability to control the flow of moisture and air as well as heat. Selecting the wrong type of insulation or placing it in the wrong wall assembly often leads to moisture accumulation with subsequent material deterioration and growth of mold.
Building America Reports
Steve Baczek, Peter Yost, Stephanie Finegan
Americans have been building homes with wood—shaping logs, joining timbers, nailing studs—for almost 400 years. Our current approach, stick framing, grew popular in the mid-1800’s (particularly in the rapidly growing “West”) because it took less skill, required simpler tools, and took fewer people than timber framing. We apparently really like waste haulers, too. The NAHB Research Center reports that the “typical” home generates about 3,500 pounds of wood waste during its construction, about half of which is solid sawn lumber. There are opportunities to use wood more efficiently at every stage of a home’s design and construction to save time, money, energy, and resources - you could call this optimum value engineering (OVE) from start to finish.
Building America Reports
Kohta Ueno
This is a report describing the test methodology and results for experiments run on two test houses at the Bonita Springs development in Fort Myers, FL. The goal was to determine the effect of attic ventilation in a hot-humid climate; previous work had shown that little to no benefit is derived from ventilation in terms of energy use, and that it is detrimental for moisture control. Two houses with identical orientations and plans were compared; one was ventilated at the typical 1:300 ratio, and the other had sealed vents. This work was conducted in order to move houses in hot-humid climates forward in technology in their building envelope and HVAC systems.
Hot-Humid
Building America Reports
Joseph Lstiburek
High performance building envelopes require controlled ventilation systems, sealed combustion appliances and allow the use of innovative air distribution systems. The optimum controlled ventilation system in all climate zones is a supply ventilation system that allows for filtration of outside supply air and the pressurization of building enclosures to exclude environmental contaminants. The high performance aspects of the building envelopes allow for the simplification of duct distribution systems. Advanced space conditioning involves the integration of a building’s heating, ventilating and air conditioning (HVAC) system with the building enclosure or building envelope.
Building America Reports
Armin Rudd
Forced air distribution ducts are often hard to seal. Air leakage in ducts makes it difficult to assure that the correct quantity of air is conveyed to or from the intended space. In order to reduce duct leakage and the overall cost of installing sealed ducts, central return ducts are preferable to distributed return ducts. Our cold-climate design calls for a central return on each conditioned floor, and a separate return for the master bedroom. In order to assure that the intended amount of supply air is delivered to each secondary room without over-pressurizing the room (< 3 Pa), air transfer grilles are specified. Transfer grilles represent a cost-effective alternative to individual return ducts if they are properly configured for air flow, privacy, and aesthetics.