New buildings account for a relatively small percentage of the energy used in the building sector. Retrofitting existing housing and commercial/industrial facilities is an important goal in terms of energy savings. It is also a complex endeavor, with many factors to consider, from preserving historic features to controlling costs.
The following articles and reports discuss a wide variety of materials, situations and techniques that may be encountered when undertaking an energy-efficient retrofit. As well, many case studies are provided to illustrate how to do retrofits right.
This paper is from the proceedings of the Thermal Performance of the Exterior Envelopes of Whole Buildings XI International Conference, December 5-9, 2010 in Clearwater, Florida. This paper summarizes some of the limitations of the various approaches to assessing the freeze-thaw resistance of brick masonry units and presents a detailed methodology for using frost dilatometry to determine the critical degree of saturation of brick material. Test results are presented for bricks from several historical load-bearing masonry. Recommendations are made for applying this approach together with hygrothermal model in the design of retrofit insulation projects.
Basements can account for up to one quarter of the typical energy consumption in a house. Therefore, insulating foundations is a critical measure for achieving high performance buildings. This is important in both new construction and retrofits of existing buildings. The fundamental problems and “best practice solutions” for moisture-safe basement insulation have been well established. However, many foundations are damp (either due to bulk water or capillary “wicking” of moisture) or of a type of construction that is not easy or straightforward to insulate (such as rubble foundations). Damp foundation repair methods can be “leveraged” to provide energy efficiency benefits. An example of this “hybrid” approach is spray foam insulation, which can be an effective means of liquid phase water control (leaking basement), vapor phase water control (diffusion and air leakage transported condensation) as well as an effective insulation.
This research project developed baseline engineering analysis to support the installation of thick layers of exterior insulation (2” to 8”) on existing masonry walls and wood framed walls through the use of wood furring strips (fastened through the insulation back to the structure) as a cladding attachment location. Furthermore, water management details necessary to connect the exterior insulated wall assemblies to roofs, balconies, decks, and windows were created to provide guidance on the integration of exterior insulation strategies with other enclosure elements.