Energy efficiency is central to most definitions of high-performance buildings. It is also central to BSC’s consulting, research, and education activities. At BSC, we believe in promoting energy efficiency and environmental responsibility within the constraints of marketable and affordable building technology.
The documents below discuss why energy is critical to sustainability and how to define and understand energy use (for example, through energy metrics). They also touch on key issues in energy reduction in buildings, such as thermal control and advances in window technology for commercial and residential buildings.
Providing thermal comfort without excess space conditioning costs is one of the primary requirements of buildings. Therefore, thermal control is an important aspect in almost all buildings. Understanding heat transfer and the temperature distribution through building materials and assemblies is also important for assessing energy use, thermal comfort, thermal movements, durability, and the potential for moisture problems.
Heat flow occurs through the building enclosure via opaque enclosure elements, is directly transferred into the building by solar radiation through windows, is carried along with air across the enclosure by unintentional leakage and ventilation, and can be generated within the building by occupants and their activities.
The control of heat flow in buildings requires insulation layers compromised with few thermal bridges, an effective air barrier system, good control of solar radiation, and management of interior heat generation.
Putting metrics on building energy performance is a required step to make any progress on low-energy use and/or “green” buildings. However, there are many confusing and contradictory metrics available; to speak a common language, it is necessary to understand the topics that are behind these measurements. These topics include site vs. source energy, modeled results vs. reality, US average energy use figures, and methods of normalizing energy use. The normalization of energy use intensity (EUI), or dividing by square footage is examined; several significant problems in applying this metric to residential use are demonstrated. Various other metrics are presented, as well as a proposed method to provide all of the useful building energy information in a format that allows normalization by any chosen metric.
This report is an excerpt from the 2008 Building America Annual Report. Following the almost complete destruction of Greensburg, Kansas by a tornado in May, 2007, Building Science Corporation (BSC) was contracted to provide example house plans, support for the reconstruction of energy efficient houses and training for builders and trades. This report describes the results of BSC’s work to construct more than 20 energy efficient, affordable, durable houses in Greensburg, Kansas.