<?xml version="1.0" encoding="utf-8" ?>
<rdf:RDF xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#"
         xmlns:dc="http://purl.org/dc/elements/1.1/"
         xmlns:syn="http://purl.org/rss/1.0/modules/syndication/"
         xmlns="http://purl.org/rss/1.0/">




    



<channel rdf:about="http://www.buildingscience.com/resources/high-r-value-wall-assemblies/RSS">
  <title>High R-Value Wall Assemblies</title>
  <link>http://www.buildingscience.com</link>
  
  <description>
    
       
       
  </description>
  
  
  
            <syn:updatePeriod>daily</syn:updatePeriod>
            <syn:updateFrequency>1</syn:updateFrequency>
            <syn:updateBase>2010-01-26T02:05:02Z</syn:updateBase>
        
  
  <image rdf:resource="http://www.buildingscience.com/logo.jpg"/>

  <items>
    <rdf:Seq>
        
            <rdf:li rdf:resource="http://www.buildingscience.com/documents/information-sheets/high-r-value-wall-assemblies/high-r-wall-01-standard-wall-construction"/>
        
        
            <rdf:li rdf:resource="http://www.buildingscience.com/documents/information-sheets/high-r-value-wall-assemblies/high-r-wall-02-advanced-frame-wall-construction"/>
        
        
            <rdf:li rdf:resource="http://www.buildingscience.com/documents/information-sheets/high-r-value-wall-assemblies/high-r-wall-03-interior-strapping-construction"/>
        
        
            <rdf:li rdf:resource="http://www.buildingscience.com/documents/information-sheets/high-r-value-wall-assemblies/high-r-wall-04-double-stud-wall-construction"/>
        
        
            <rdf:li rdf:resource="http://www.buildingscience.com/documents/information-sheets/high-r-value-wall-assemblies/high-r-wall-05-truss-wall-construction"/>
        
        
            <rdf:li rdf:resource="http://www.buildingscience.com/documents/information-sheets/high-r-value-wall-assemblies/high-r-wall-06-sips-wall-construction"/>
        
        
            <rdf:li rdf:resource="http://www.buildingscience.com/documents/information-sheets/high-r-value-wall-assemblies/high-r-wall-07-icf-wall-construction"/>
        
        
            <rdf:li rdf:resource="http://www.buildingscience.com/documents/information-sheets/high-r-value-wall-assemblies/high-r-wall-08-spray-foam-wall-construction"/>
        
        
            <rdf:li rdf:resource="http://www.buildingscience.com/documents/information-sheets/high-r-value-wall-assemblies/high-r-wall-09-flash-and-fill-hybrid-wall-construction"/>
        
        
            <rdf:li rdf:resource="http://www.buildingscience.com/documents/information-sheets/high-r-value-wall-assemblies/high-r-wall-11-offset-frame-wall"/>
        
        
            <rdf:li rdf:resource="http://www.buildingscience.com/documents/information-sheets/high-r-value-wall-assemblies/high-r-wall-12-exterior-insulation-finish-systems-eifs-wall-construction"/>
        
        
            <rdf:li rdf:resource="http://www.buildingscience.com/documents/reports/rr-0903-building-america-special-research-project-high-r-walls"/>
        
        
            <rdf:li rdf:resource="http://www.buildingscience.com/documents/reports/rr-1005-building-america-high-r-value-high-performance-residential-buildings-all-climate-zones"/>
        
        
            <rdf:li rdf:resource="http://www.buildingscience.com/documents/reports/rr-1014-high-r-walls-pacific-northwest-hygrothermal-analysis"/>
        
    </rdf:Seq>
  </items>

</channel>

    <item rdf:about="http://www.buildingscience.com/documents/information-sheets/high-r-value-wall-assemblies/high-r-wall-01-standard-wall-construction">        <title>High R-Value Wall Assembly-01: Standard Wall Construction</title>        <link>http://www.buildingscience.com/documents/information-sheets/high-r-value-wall-assemblies/high-r-wall-01-standard-wall-construction</link>        <description>Constructing high R-value walls is the first and easiest step in reducing the whole house energy consumption. But first a reference wall is needed for comparison.</description>        <dc:publisher>No publisher</dc:publisher>        <dc:creator>Building Science Corporation</dc:creator>        <dc:rights></dc:rights>                    <dc:subject>enclosure-Wall assembly</dc:subject>                    <dc:subject>Building America</dc:subject>                    <dc:subject>climate-Building design and climate</dc:subject>                    <dc:subject>doc-EnclosuresThatWork</dc:subject>                <dc:date>2013-04-02T21:14:21Z</dc:date>        <dc:type>BSC Article</dc:type>    </item>
    <item rdf:about="http://www.buildingscience.com/documents/information-sheets/high-r-value-wall-assemblies/high-r-wall-02-advanced-frame-wall-construction">        <title>High R-Value Wall Assembly-02: 2x6 Advanced Frame Wall Construction</title>        <link>http://www.buildingscience.com/documents/information-sheets/high-r-value-wall-assemblies/high-r-wall-02-advanced-frame-wall-construction</link>        <description>This information sheet summarizes advanced wall construction with insulated sheathing, including the advantages and disadvantages of this construction strategy. </description>        <dc:publisher>No publisher</dc:publisher>        <dc:creator>Building Science Corporation</dc:creator>        <dc:rights></dc:rights>                    <dc:subject>Building America</dc:subject>                    <dc:subject>doc-EnclosuresThatWork</dc:subject>                <dc:date>2013-04-02T21:10:37Z</dc:date>        <dc:type>BSC Article</dc:type>    </item>
    <item rdf:about="http://www.buildingscience.com/documents/information-sheets/high-r-value-wall-assemblies/high-r-wall-03-interior-strapping-construction">        <title>High R-Value Wall Assembly-03: Interior Strapping Wall Construction</title>        <link>http://www.buildingscience.com/documents/information-sheets/high-r-value-wall-assemblies/high-r-wall-03-interior-strapping-construction</link>        <description>This information sheet summarizes interior strapping wall construction including the advantages and disadvantages of this construction strategy.</description>        <dc:publisher>No publisher</dc:publisher>        <dc:creator>Building Science Corporation</dc:creator>        <dc:rights></dc:rights>                    <dc:subject>Building America</dc:subject>                    <dc:subject>doc-EnclosuresThatWork</dc:subject>                <dc:date>2013-04-02T21:12:19Z</dc:date>        <dc:type>BSC Article</dc:type>    </item>
    <item rdf:about="http://www.buildingscience.com/documents/information-sheets/high-r-value-wall-assemblies/high-r-wall-04-double-stud-wall-construction">        <title>High R-Value Wall Assembly-04: Double Stud Wall Construction</title>        <link>http://www.buildingscience.com/documents/information-sheets/high-r-value-wall-assemblies/high-r-wall-04-double-stud-wall-construction</link>        <description>This information sheet summarizes double stud wall construction, including the advantages and disadvantages of this construction strategy. </description>        <dc:publisher>No publisher</dc:publisher>        <dc:creator>Building Science Corporation</dc:creator>        <dc:rights></dc:rights>                    <dc:subject>Building America</dc:subject>                    <dc:subject>doc-EnclosuresThatWork</dc:subject>                <dc:date>2013-04-02T21:15:44Z</dc:date>        <dc:type>BSC Article</dc:type>    </item>
    <item rdf:about="http://www.buildingscience.com/documents/information-sheets/high-r-value-wall-assemblies/high-r-wall-05-truss-wall-construction">        <title>High R-Value Wall Assembly-05: Truss Wall Construction</title>        <link>http://www.buildingscience.com/documents/information-sheets/high-r-value-wall-assemblies/high-r-wall-05-truss-wall-construction</link>        <description>This information sheet summarizes truss wall construction including the advantages and disadvantages of this construction strategy.</description>        <dc:publisher>No publisher</dc:publisher>        <dc:creator>Building Science Corporation</dc:creator>        <dc:rights></dc:rights>                    <dc:subject>Building America</dc:subject>                    <dc:subject>doc-EnclosuresThatWork</dc:subject>                <dc:date>2013-04-02T21:17:14Z</dc:date>        <dc:type>BSC Article</dc:type>    </item>
    <item rdf:about="http://www.buildingscience.com/documents/information-sheets/high-r-value-wall-assemblies/high-r-wall-06-sips-wall-construction">        <title>High R-Value Wall Assembly-06: SIPs Wall Construction</title>        <link>http://www.buildingscience.com/documents/information-sheets/high-r-value-wall-assemblies/high-r-wall-06-sips-wall-construction</link>        <description>This information sheet summarizes structural insulated panel (SIPs) wall construction, including the advantages and disadvantages of this construction strategy. </description>        <dc:publisher>No publisher</dc:publisher>        <dc:creator>Building Science Corporation</dc:creator>        <dc:rights></dc:rights>                    <dc:subject>Building America</dc:subject>                    <dc:subject>doc-EnclosuresThatWork</dc:subject>                <dc:date>2013-04-02T21:18:40Z</dc:date>        <dc:type>BSC Article</dc:type>    </item>
    <item rdf:about="http://www.buildingscience.com/documents/information-sheets/high-r-value-wall-assemblies/high-r-wall-07-icf-wall-construction">        <title>High R-Value Wall Assembly-07: ICF Wall Construction</title>        <link>http://www.buildingscience.com/documents/information-sheets/high-r-value-wall-assemblies/high-r-wall-07-icf-wall-construction</link>        <description>This information sheet summarizes insulated concrete form (ICF) wall construction, including the advantages and disadvantages of this construction strategy. </description>        <dc:publisher>No publisher</dc:publisher>        <dc:creator>Building Science Corporation</dc:creator>        <dc:rights></dc:rights>                    <dc:subject>Building America</dc:subject>                    <dc:subject>doc-EnclosuresThatWork</dc:subject>                <dc:date>2013-04-02T21:20:15Z</dc:date>        <dc:type>BSC Article</dc:type>    </item>
    <item rdf:about="http://www.buildingscience.com/documents/information-sheets/high-r-value-wall-assemblies/high-r-wall-08-spray-foam-wall-construction">        <title>High R-Value Wall Assembly-08: Spray Foam Wall Construction</title>        <link>http://www.buildingscience.com/documents/information-sheets/high-r-value-wall-assemblies/high-r-wall-08-spray-foam-wall-construction</link>        <description>This information sheet summarizes spray foam wall construction including the advantages and disadvantages of this construction strategy.</description>        <dc:publisher>No publisher</dc:publisher>        <dc:creator>Building Science Corporation</dc:creator>        <dc:rights></dc:rights>                    <dc:subject>Building America</dc:subject>                    <dc:subject>doc-EnclosuresThatWork</dc:subject>                <dc:date>2013-04-02T21:21:40Z</dc:date>        <dc:type>BSC Article</dc:type>    </item>
    <item rdf:about="http://www.buildingscience.com/documents/information-sheets/high-r-value-wall-assemblies/high-r-wall-09-flash-and-fill-hybrid-wall-construction">        <title>High R-Value Wall Assembly-09: Flash-and-Fill Hybrid Wall Construction</title>        <link>http://www.buildingscience.com/documents/information-sheets/high-r-value-wall-assemblies/high-r-wall-09-flash-and-fill-hybrid-wall-construction</link>        <description>This information sheet summarizes flash-and-fill hybrid wall construction including the advantages and disadvantages of this construction strategy.</description>        <dc:publisher>No publisher</dc:publisher>        <dc:creator>Building Science Corporation</dc:creator>        <dc:rights></dc:rights>                    <dc:subject>Building America</dc:subject>                    <dc:subject>doc-EnclosuresThatWork</dc:subject>                <dc:date>2013-04-02T21:23:18Z</dc:date>        <dc:type>BSC Article</dc:type>    </item>
    <item rdf:about="http://www.buildingscience.com/documents/information-sheets/high-r-value-wall-assemblies/high-r-wall-11-offset-frame-wall">        <title>High R-Value Wall Assembly-11: Offset Frame Wall Construction</title>        <link>http://www.buildingscience.com/documents/information-sheets/high-r-value-wall-assemblies/high-r-wall-11-offset-frame-wall</link>        <description>This information sheet summarizes offset frame wall construction including the advantages and disadvantages of this construction strategy.</description>        <dc:publisher>No publisher</dc:publisher>        <dc:creator>Building Science Corporation</dc:creator>        <dc:rights></dc:rights>                    <dc:subject>Building America</dc:subject>                    <dc:subject>doc-EnclosuresThatWork</dc:subject>                <dc:date>2013-04-02T21:26:14Z</dc:date>        <dc:type>BSC Article</dc:type>    </item>
    <item rdf:about="http://www.buildingscience.com/documents/information-sheets/high-r-value-wall-assemblies/high-r-wall-12-exterior-insulation-finish-systems-eifs-wall-construction">        <title>High R-Value Wall Assembly-12: Exterior Insulation Finish Systems (EIFS) Wall Construction</title>        <link>http://www.buildingscience.com/documents/information-sheets/high-r-value-wall-assemblies/high-r-wall-12-exterior-insulation-finish-systems-eifs-wall-construction</link>        <description>This information sheet summarizes Exterior Insulation Finish Systems (EIFS), including the advantages and disadvantages of this construction strategy.</description>        <dc:publisher>No publisher</dc:publisher>        <dc:creator>Building Science Corporation</dc:creator>        <dc:rights></dc:rights>                    <dc:subject>Building America</dc:subject>                    <dc:subject>doc-EnclosuresThatWork</dc:subject>                <dc:date>2013-04-02T21:27:31Z</dc:date>        <dc:type>BSC Article</dc:type>    </item>
    <item rdf:about="http://www.buildingscience.com/documents/reports/rr-0903-building-america-special-research-project-high-r-walls">        <title>RR-0903: Building America Special Research Project—High-R Walls Case Study Analysis</title>        <link>http://www.buildingscience.com/documents/reports/rr-0903-building-america-special-research-project-high-r-walls</link>        <description>This report considers a number of promising wall systems that can meet the requirement for better thermal control. Unlike previous studies, this one considers performance in a more realistic matter, including some true three-dimensional heat flow and the relative risk of moisture damage.</description>        <dc:publisher>No publisher</dc:publisher>        <dc:creator>John Straube and Jonathan Smegal</dc:creator>        <dc:rights></dc:rights>                    <dc:subject>advanced framing</dc:subject>                    <dc:subject>enclosure-Wall assembly</dc:subject>                    <dc:subject>thermal-Physics of Thermal Control</dc:subject>                    <dc:subject>enclosure-Wall assembly-sheathing</dc:subject>                    <dc:subject>energy</dc:subject>                    <dc:subject>EIFS</dc:subject>                    <dc:subject>airflow-Physics of Air Movement</dc:subject>                    <dc:subject>high-R wall</dc:subject>                    <dc:subject>guidance-Enclosure design principles</dc:subject>                    <dc:subject>enclosure-Wall assembly-siding</dc:subject>                    <dc:subject>Building America</dc:subject>                    <dc:subject>analysis-Hygrothermal modelling</dc:subject>                    <dc:subject>doc-Report</dc:subject>                    <dc:subject>enclosure-Wall assembly-insulation</dc:subject>                    <dc:subject>airflow-Driving forces/stack effect</dc:subject>                    <dc:subject>enclosure-Wall assembly-drywall</dc:subject>                    <dc:subject>climate-Building design and climate</dc:subject>                <dc:date>2013-04-09T21:37:56Z</dc:date>        <dc:type>BSC File</dc:type>    </item>
    <item rdf:about="http://www.buildingscience.com/documents/reports/rr-1005-building-america-high-r-value-high-performance-residential-buildings-all-climate-zones">        <title>RR-1005: Building America Special Research Project: High R-Value Enclosures for High Performance Residential Buildings in All Climate Zones</title>        <link>http://www.buildingscience.com/documents/reports/rr-1005-building-america-high-r-value-high-performance-residential-buildings-all-climate-zones</link>        <description>The following report is an excerpt from the 2010 Building Science Corporation Industry Team Building America Annual Report. Many concerns, including the rising cost of energy, climate change concerns, and demands for increased comfort, have lead to the desire for increased insulation levels in many new and existing buildings. Building codes and green building codes are being changed to require higher levels of thermal insulation both for residential and commercial construction. This report will review, and summarize the current state of understanding and research into enclosures with higher thermal resistance, so-called “High-R
Enclosures”.  Recommendations are provided for further research.</description>        <dc:publisher>No publisher</dc:publisher>        <dc:creator>John Straube</dc:creator>        <dc:rights></dc:rights>                    <dc:subject>guidance-Enclosure design principles</dc:subject>                    <dc:subject>high-performance</dc:subject>                    <dc:subject>resources-technical</dc:subject>                    <dc:subject>high-R wall</dc:subject>                    <dc:subject>Building America</dc:subject>                    <dc:subject>high performance</dc:subject>                    <dc:subject>doc-Report</dc:subject>                    <dc:subject>climate-Building design and climate</dc:subject>                <dc:date>2013-04-09T20:10:17Z</dc:date>        <dc:type>BSC File</dc:type>    </item>
    <item rdf:about="http://www.buildingscience.com/documents/reports/rr-1014-high-r-walls-pacific-northwest-hygrothermal-analysis">        <title>RR-1014: High-R Walls for the Pacific Northwest–A Hygrothermal Analysis of Various Exterior Wall Systems</title>        <link>http://www.buildingscience.com/documents/reports/rr-1014-high-r-walls-pacific-northwest-hygrothermal-analysis</link>        <description>This report considers a number of promising wall systems that can meet the requirement for better thermal control. Unlike previous studies, this one considers performance in a more realistic matter, including some two- and three-dimensional heat flow and analysis of the relative risk of moisture damage.</description>        <dc:publisher>No publisher</dc:publisher>        <dc:creator>Jonathan Smegal and John Straube</dc:creator>        <dc:rights></dc:rights>                    <dc:subject>enclosure-Wall assembly</dc:subject>                    <dc:subject>guidance-Enclosure design principles</dc:subject>                    <dc:subject>high-R wall</dc:subject>                    <dc:subject>analysis-Hygrothermal modelling</dc:subject>                    <dc:subject>doc-Report</dc:subject>                    <dc:subject>climate-zone-marine</dc:subject>                <dc:date>2013-04-09T21:16:42Z</dc:date>        <dc:type>BSC File</dc:type>    </item>




</rdf:RDF>
