Freeze-Thaw Damage

Masonry walls are generally highly durable. However, when masonry walls in cold climates stay too wet for too long, freeze-thaw damage can occur. This issue has particular relevance for energy efficiency retrofits, because the addition of interior insulation causes the masonry to stay colder and have a lower drying potential.

The following documents present details of BSC’s research and experience regarding the prevention of freeze-thaw damage in retrofit projects. Technical topics such as the critical degree of saturation (Scrit) are discussed, and case studies and recommendations are provided.

1-19 of 19 Items
BA

BA-1505: Measure Guideline—Deep Energy Enclosure Retrofit (DEER) for Interior Insulation of Masonry Walls

By Sravanthi Musunuru and Betsy Pettit
Download.pdf  3.1 MB

BA

BA-1404: Initial and Long Term Movement of Cladding Installed Over Exterior Rigid Insulation

By Peter Baker
Download.pdf  2.8 MB

BA

BA-1403: Guidance on Modeling Enclosure Design in Above Grade Walls: Expert Meeting Report

By Kohta Ueno and Joseph Lstiburek
Download.pdf  4.4 MB

BA

BA-1314: Cladding Attachment Over Thick Exterior Insulating Sheathing

By Peter Baker and Robert Lepage
Download.pdf  3.7 MB

BA

BA-1311: Evaluation of Two CEDA Weatherization Pilot Implementations of an Exterior Insulation and Over-Clad Retrofit Strategy for Residential Masonry Buildings in Chicago

By Ken Neuhauser
Download.pdf  7.2 MB

GM

Mass Save Deep Energy Retrofit Builder Guide

By Betsy Pettit, FAIA, Ken Neuhauser, Cathy Gates
Download.pdf  6.1 MB

BA

BA-1307: Interior Insulation of Mass Masonry Walls: Joist Monitoring, Material Test Optimization, Salt Effects

By Kohta Ueno, Randy Van Straaten, Chris Schumacher
Download.pdf  6.9 MB

BA

BA-1302: Retrofit of a Multi-family Mass Masonry Building in New England

By Ueno/Kerrigan/Wytrykowska/Van Straaten
Download.pdf  15.5 MB

BA

BA-1202: Byggmeister Test Home—Cold Climate Multifamily Masonry Building Condition Assessment and Retrofit Analysis

By Honorata Wytrykowska, Kohta Ueno, Randy Van Straaten
Download.pdf  7.4 MB

BA

BA-1204: External Insulation of Masonry Walls and Wood Framed Walls

By Peter Baker
Download.pdf  12.4 MB

BA

BA-1108: Hybrid Foundation Insulation Retrofits: Measure Guidelines

By Kohta Ueno and Joseph Lstiburek
Download.pdf  4.5 MB

BA

BA-1105: Internal Insulation of Masonry Walls: Final Measure Guideline

By John Straube, Kohta Ueno and Christopher Schumacher
Download.pdf  6.8 MB

RR

RR-1014: High-R Walls for the Pacific Northwest–A Hygrothermal Analysis of Various Exterior Wall Systems

By Jonathan Smegal and John Straube
Download.pdf  2.6 MB

BA

BA-1015: Bulk Water Control Methods for Foundations

By Kohta Ueno and Joseph Lstiburek
Download.pdf  3.4 MB

RR

RR-0406: Face Sealed vs. Drainable EIFS

By Joseph Lstiburek
Download.pdf  1.3 MB

BA

BA-0903: Building America Special Research Project—High-R Walls Case Study Analysis

By John Straube and Jonathan Smegal
Download.pdf  6.7 MB

RR

RR-0106: Problems with Housewraps

By Joseph Lstiburek
Download.pdf  494.3 KB

RR

RR-0409: Painting

By Joseph Lstiburek
Download.pdf  588.6 KB

RR

RR-0410: Vapor Barriers and Wall Design

By Joseph Lstiburek
Download.pdf  2.1 MB

1-19 of 19 Items