Flooring in commercial and residential buildings can have a variety of problems, from moldy carpets to debonded vinyl tiles to movement in wood flooring. Understanding the causes and solutions of these problems involves understanding the building as a system. What happens beneath and above a floor matters, in ways that aren’t always anticipated or well understood.
The articles in this section examine a range of building practices and materials – and the interactions between them – that can lead to flooring problems and solutions.
Although this article is titled "Mold Testing" it actually tells you why testing for mold is usually not needed.
Primarily as a resort location, Hilton Head Island has a somewhat different residential housing market than other more traditional areas.
Given what happened in New Orleans during hurricane Katrina, changes in the way we build are needed. Looking to key sustainability concepts of durability and energy efficiency, new flood resistant design concepts were developed.
Concentrations of 54 volatile organic compounds (VOCs) and ventilation rates were measured in four new manufactured houses over 2-to-9.5 months following installation and in seven new site-built houses 1-to-2 months after completion. The houses were in four projects located in hot-humid and mixed-humid climates. They were finished and operational, but unoccupied.
The following reports are excerpts from the 2009 Building Science Corporation Industry Team Building America Annual Report. These summaries are for the following advanced system research projects: high R-value enclosures, ventilation effectiveness advanced system research, and dehumidification performance advanced system research.
Successfully executing strategies to control bulk water for foundations is critical for building durability, indoor air quality, and creating acceptable conditions and/or living spaces within the foundation space. Although the energy impacts of properly done bulk water control are small to insignificant, it should be considered a base requirement for any high performance house. In addition, measures such as basement insulation are predicated on properly managed foundation bulk water.
Load-bearing masonry buildings are a significant portion of the existing building stock. Given the Building America goals of reducing home energy use by 30%-50% (compared to 2009 energy codes for new homes and pre-retrofit energy use for existing homes), insulation and air sealing of mass masonry walls will need to be a component of this work if mass masonry residential buildings are to be addressed.
Building Science Corporation seeks to further the energy efficiency market for cold climate, New England area retrofits by supporting projects based on solid building science fundamentals and verified implementation. The utility company National Grid engaged BSC as a partner to develop guidelines for its Deep Energy Retrofit Pilot Program. In addition to guideline development, BSC has acted as a consultant for these projects and others following similar retrofit strategies.
Through discussion of five case studies (test homes), this project evaluates strategies to elevate the performance of existing homes to a level commensurate with best-in-class implementation of high performance new construction homes. The test homes featured in this research activity participated in Deep Energy Retrofit (DER) Pilot Program sponsored by the electric and gas utility National Grid in Massachusetts and Rhode Island. Retrofit strategies are evaluated for impact on durability and indoor air quality in addition to energy performance.
There is a large existing stock of uninsulated mass masonry buildings: their uninsulated walls result in poor energy performance, which is commonly addressed with the retrofit of interior insulation. Some durability issues associated with interior insulation have been or are being addressed, such as interstitial condensation and freeze-thaw damage issues. However, another durability risk is the hygrothermal behavior of moisture-sensitive wood beams embedded in the load-bearing masonry. Interior insulation reduces the beam end temperatures, reduces available drying potential, and results in higher relative humidity conditions in the beam pocket: all of these factors pose a greater risk to durability.
Building Science Corporation (BSC) has been working with Byggmeister, a partner on the Building America (BA) team, on retrofit projects under the BA program. Byggmeister is a local design-build firm that specializes in energy efficient retrofits and new construction. The Duclos, Eldrenkamp and Panish Energy Group (DEEP Energy Group), which is associated with Byggmeister, conducts design-phase energy analysis and monitors completed projects. The Byggmeister multifamily test home located in Jamaica Plain, Massachusetts (Jamaica Plain or J.P. Three-Family) is a three-story brick row house . The test home is examined with the goal of producing a case study that could be applied to similar New England homes. Basic areas of research that this report is expected to contribute include finding the combination of measures that are feasible, affordable, and suitable for this type of construction and acceptable to homeowners.
This measure guideline provides information and guidance about rehabilitating, retrofitting, and replacing wood window assemblies in residential construction. It is intended primarily to help contractors and homeowners understand the options for safely improving the performance of their wood windows.
Merrimack Valley Habitat for Humanity (MVHfH) has partnered with Building Science Corporation to provide high performance affordable housing for 10 families in the retrofit of an existing brick building (a former convent) into condominiums. The condominium conversion project will contribute to several areas of space conditioning, water heating, and enclosures research. Enclosure items include insulation of mass masonry building on the interior, airtightness of these types of retrofits, multi-unit building compartmentalization, window selection and roof insulation strategies. Mechanical system items include combined hydronic and space heating systems with hydronic distribution in small (low load) units, and ventilation system retrofits for multifamily buildings.