Research Reports are technical reports written for researchers but accessible to design professionals and builders. These reports typically provide an in-depth study of a particular topic or describe the results of a research project. They are often peer reviewed and also provide support for advice given in our Building Science Digests. The most recent documents posted are at the top of the list below.
Project Home Again is a development in New Orleans, Louisiana, created to provide new homes to victims of Hurricane Katrina. Building Science Corporation (BSC) acted as a consultant for the project, advocating design strategies for durability, flood resistance, occupant comfort, and low energy use while maintaining cost effectiveness. These techniques include the use of high density spray foam insulation, LowE3 glazing, and supplemental dehumidification to maintain comfortable humidity levels without unnecessary cooling. Stringent airtightness goals were achieved by the project, helping to meet the Builder’s Challenge targets set by Project Home Again. Floor plans, enclosures, and heating, ventilation, and air conditioning attributes are quite similar among different homes in the project.
The following report is an excerpt from the 2010 Building Science Corporation Industry Team Building America Annual Report. The main focus for this research project is on the AAON heat pump system with digital scroll compressor and modulating hot-gas condenser reheat installed in the GreenCraft Builders prototype house in Lewisville, TX.
A calibrated ventilation model was exercised over a range of parameters seen in new and existing housing in the United States. This report was first published in ASHRAE Transactions (17, Louisville 2009). American Society of Heating Refrigeration and Air-Conditioning Engineers, Atlanta, GA. Reprinted with permission.
A performance review of residential assemblies in the central Florida (Orlando) area during the three hurricanes in August and September 2004.
Concentrations of 54 volatile organic compounds (VOCs) and ventilation rates were measured in four new manufactured houses over 2-to-9.5 months following installation and in seven new site-built houses 1-to-2 months after completion. The houses were in four projects located in hot-humid and mixed-humid climates. They were finished and operational, but unoccupied.
Given what happened in New Orleans during hurricane Katrina, changes in the way we build are needed. Looking to key sustainability concepts of durability and energy efficiency, new flood resistant design concepts were developed.
Primarily as a resort location, Hilton Head Island has a somewhat different residential housing market than other more traditional areas.
When constructing unvented roofs with asphalt shingles in hot-humid climates, a vapor barrier must be installed between the asphalt shingles and the roof deck.
Twenty homes were tested and monitored in the hot-humid climate of Houston, Texas, to evaluate the humidity control performance and operating cost of six different integrated dehumidification and ventilation systems that could be applied by production homebuilders.
Indoor moisture and temperature conditions and equipment operation were measured and analyzed for 43 homes in warm-humid and mixed-humid climate regions of the United States.
Humidity concerns in the southern humid climates are particularly difficult to resolve. This is because one of the most effective approaches to dealing with humidity in heating climates, ventilation, can cause major humidity problems in the humid south.
This report summarizes indoor temperature and humidity data that have been collected from houses by the Building Science Consortium of the US Department of Energy Building America Program.
The overall goal of the DOE residential research program is to reduce average whole house energy use in new residential buildings by 30-90 percent by 2020, including homes that achieve zero net energy use on an annual basis. High performance space conditioning and control systems that match the high performance of Building America enclosures are necessary to meet performance targets. Conditioning systems with integrated mechanical ventilation and year-around temperature and humidity control are necessary. The most significant climate-specific need is for system-integrated dehumidification for humidity control without overcooling the space. Cost-effective dehumidification without overcooling will enable continued and further reduction of sensible loads (including high-performance glazing) that would otherwise exacerbate humidity control problems in humid climates.
An examination of five different systems that show how to cool and dehumidify inside air while maintaining sufficient introduction of outside air for ventilation efficiently and cost-effectively.
Twenty homes were tested and monitored in the hot-humid climate of Houston, Texas, U.S.A., to evaluate the humidity control performance and operating cost of six different integrated dehumidification and ventilation systems that could be applied by production homebuilders. Fourteen houses, that also met measured energy efficiency criteria, had one of the six directly- or indirectly-integrated dehumidification and ventilation systems. Three reference houses had the same energy efficiency measures and controlled mechanical ventilation, while three other reference houses met code minimums for energy efficiency and did not have mechanical ventilation. Temperature and relative humidity were monitored at four living-space locations and in the conditioned attic where the space-conditioning equipment and air-distribution ducts were located. Equipment operational time was monitored for heating, cooling, dehumidification, and ventilation. Results showed that energy efficiency measures, combined with controlled mechanical ventilation, change the sensible and latent cooling load fractions such that supplemental dehumidification, in addition to that provided by the central cooling system, is required to maintain indoor relative humidity below 60% throughout the year. The system providing the best overall value, including humidity control, first cost, and operating cost, involved a standard dehumidifier located in a hall closet with a louvered door and central-fan-integrated supply ventilation with fan cycling.
This is a report describing the test methodology and results for experiments run on two test houses at the Bonita Springs development in Fort Myers, FL. The goal was to determine the effect of attic ventilation in a hot-humid climate; previous work had shown that little to no benefit is derived from ventilation in terms of energy use, and that it is detrimental for moisture control. Two houses with identical orientations and plans were compared; one was ventilated at the typical 1:300 ratio, and the other had sealed vents. This work was conducted in order to move houses in hot-humid climates forward in technology in their building envelope and HVAC systems.
Current work is focusing on the performance and durability of unvented-cathedralized attics in hot-humid climates with both tile and asphalt shingle roofing.
The effects of solar heating potential and nocturnal cooling potential are simulated in a controlled indoor environment and extensive measurements are made along and between the boundary surfaces. Air delivered to the test section is controlled to close tolerances in temperature, humidity and flow rate. Steady state conditions, step changes, functional changes or real weather conditions can be simulated. Accurate measurements are taken at the inlet and outlet of the test section to determine the amount of heat and mass transfer across the system. The facility is completely computer controlled. The control software, employing a self-tuning proportional integral control methodology, was developed in house. A description of both the DESRAD concept and the Diurnal Test Facility is presented here along with examples of the model verification data and a brief measurement uncertainty analysis.