Research Reports are technical reports written for researchers but accessible to design professionals and builders. These reports typically provide an in-depth study of a particular topic or describe the results of a research project. They are often peer reviewed and also provide support for advice given in our Building Science Digests. The most recent documents posted are at the top of the list below.
This report summarizes hygrothermal analysis of specific attics constructed in California. The analysis was done using historical experience, published work in journals and trade publications, current building code requirements and WUFI hygrothermal simulations to assess benefits and risks associated with insulating the roof decks in both vented and unvented configurations. The majority of the configurations evaluated are well understood and have been addressed in previous published work or in the model building codes. However, the focus of this report is on modifying conventional, ventilated attics, constructed with impermeable roof shingles (with fiberglass batt insulation on the ceiling plane) by adding fiberglass batt (or netted fiberglass or netted cellulose or spray applied fiberglass) insulation to the underside of the roof deck (i.e. on the slope) while leaving the attic air space ventilated to outdoors.
A single-story, single-family, 1350 sq. ft. house located in Las Vegas, NV was outfitted with two separate ventilation systems. The systems were independent of each other, and were operated at different times to evaluate the relative difference in air change rate and distribution of ventilation air induced by their operation.
The overall goal of the DOE residential research program is to reduce average whole house energy use in new residential buildings by 30-90 percent by 2020, including homes that achieve zero net energy use on an annual basis. High performance space conditioning and control systems that match the high performance of Building America enclosures are necessary to meet performance targets. Conditioning systems with integrated mechanical ventilation and year-around temperature and humidity control are necessary. The most significant climate-specific need is for system-integrated dehumidification for humidity control without overcooling the space. Cost-effective dehumidification without overcooling will enable continued and further reduction of sensible loads (including high-performance glazing) that would otherwise exacerbate humidity control problems in humid climates.