Research Reports are technical reports written for researchers but accessible to design professionals and builders. These reports typically provide an in-depth study of a particular topic or describe the results of a research project. They are often peer reviewed and also provide support for advice given in our Building Science Digests. The most recent documents posted are at the top of the list below.
This report summarizes hygrothermal analysis of specific attics constructed in California. The analysis was done using historical experience, published work in journals and trade publications, current building code requirements and WUFI hygrothermal simulations to assess benefits and risks associated with insulating the roof decks in both vented and unvented configurations. The majority of the configurations evaluated are well understood and have been addressed in previous published work or in the model building codes. However, the focus of this report is on modifying conventional, ventilated attics, constructed with impermeable roof shingles (with fiberglass batt insulation on the ceiling plane) by adding fiberglass batt (or netted fiberglass or netted cellulose or spray applied fiberglass) insulation to the underside of the roof deck (i.e. on the slope) while leaving the attic air space ventilated to outdoors.
The software CONTAM was used to create a calibrated mulit-zone model to replicate in-field tracer gas decay measurements of a new two story, 2,600 sq. ft., single-family house in Sacramento, CA under different whole-house dilution ventilation scenarios. This report was first published in ASHRAE Transactions (17, Louisville 2009). American Society of Heating Refrigeration and Air-Conditioning Engineers, Atlanta, GA. Reprinted with permission.
A calibrated ventilation model was exercised over a range of parameters seen in new and existing housing in the United States. This report was first published in ASHRAE Transactions (17, Louisville 2009). American Society of Heating Refrigeration and Air-Conditioning Engineers, Atlanta, GA. Reprinted with permission.
Exterior insulation and finishing systems (EIFS) are inherently defective and unfit of use as an exterior cladding system where moisture sensitive components are used without a provision for drainage or in locations and assemblies without adequate drying.
This paper reports on field measurements collected from over a year of monitoring two types of wood-framed walls: one with an air gap membrane and another installed following standard practice. Each type of wall was faced either north or south in a test hut located in southwestern Ontario.
Uniform distribution of outside air is one way to ensure that residential dilution ventilation systems will provide a known amount of fresh air to all rooms regardless of house geometry and occupant behavior.
In order for dilution ventilation systems to provide predictable results independent of the geometry of individual homes, outside air must be uniformly distributed throughout the house
A single-story, single-family, 1350 sq. ft. house located in Las Vegas, NV was outfitted with two separate ventilation systems. The systems were independent of each other, and were operated at different times to evaluate the relative difference in air change rate and distribution of ventilation air induced by their operation.
Traditionally, building codes have required that attics of residential buildings be vented. The ventilation requirement varies between one square foot of net free ventilation area per 300 square feet of attic floor area (1:300) to one square foot per 150 square feet (1:150).
Sealed attic construction, by excluding vents to the exterior, can be a good way to exclude moisture-laden outside air from attic and may offer a more easily constructed alternative for air leakage control at the top of residential buildings.
Ventilation air change rate, local mean age-of-air, and interzonal ventilation air distribution were measured for two single-family homes and eight ventilation systems.
Current work is focusing on the performance and durability of unvented-cathedralized attics in hot-humid climates with both tile and asphalt shingle roofing.
A residential attic model, contained in the finite element computer program FSEC 3.0, was empirically aligned with measured attic data from three roof research facilities in Florida and Illinois.