Research Reports are technical reports written for researchers but accessible to design professionals and builders. These reports typically provide an in-depth study of a particular topic or describe the results of a research project. They are often peer reviewed and also provide support for advice given in our Building Science Digests. The most recent documents posted are at the top of the list below.
This report is an excerpt from the 2008 Building America Annual Report. Following the almost complete destruction of Greensburg, Kansas by a tornado in May, 2007, Building Science Corporation (BSC) was contracted to provide example house plans, support for
the reconstruction of energy efficient houses and training for builders and trades. This report describes the planning, execution, and results of BSC’s builder training program in Greensburg.
This report is an excerpt from the 2008 Building America Annual Report. Following the almost complete destruction of Greensburg, Kansas by a tornado in May, 2007, Building Science Corporation (BSC) was contracted to provide example house plans, support for the reconstruction of energy efficient houses and training for builders and trades. This report describes the results of BSC’s work to construct more than 20 energy efficient, affordable, durable houses in Greensburg, Kansas.
Brick is a reservoir cladding, meaning that it absorbs and stores water (rain) when it becomes wet. In some homes, with brick veneer cladding systems, mold contamination has occurred within exterior wall cavities. In some homes, wood decay at bottom plates has also occurred.
This paper discusses Building America whole house systems research within the broad effort to reduce or eliminate the environmental impact of building and provides specific recommendations for future Building America research based on Building Science Corporation’s experience with several recent projects involving green home building programs.
Unvented roof systems can be safely used in many different climates. In cold climates, insulating sheathing must be added exterior to the roof sheathing to prevent condensation on the underside of the roof sheathing.
Two seemingly innocuous requirements for building enclosure assemblies bedevil builders and designers almost endlessly: keep water vapor out, let the water vapor out if it gets in.
Just about everyone in the building industry can be guilty of using building terms loosely, and a prime example is with attics, roof assemblies.
Heat loss through uninsulated basement walls can account for up to one-third of the heat loss from an average home. Installing insulation on basement walls is often inexpensive, easy to accomplish and frequently combined with “finishing the basement.”
A concise explanation of how a high performance HVAC system works in a high performance home.
PV systems have come a long way in the last two decades. While they may not work for all homes, residential installations are becoming a practical reality under more and more conditions
This article briefly repeats some of the information in the other mold articles but also includes information on how to prevent mold in residential structures.
This article provides both general guidelines for mold remediation as well as specific guidelines for the typical locations where mold is most often found in houses.
Although this article is titled "Mold Testing" it actually tells you why testing for mold is usually not needed.
Everything you ever wanted to know about HVAC for homes-thermal comfort, air distribution, nature of and dealing with contaminants, HVAC strategies, and climate-appropriate graphics to boot.
This article answers your questions about mold, what it is, where it grows, how it spreads, how can I prevent it.
Wood moves. Drywall does not move. Interesting problem. The more you attach drywall to wood, the more cracks you have. Easy, attach the drywall to less wood, and, in a way, that allows the wood to move.
The primary function of a housewrap or building paper is rain penetration control. It is not air infiltration despite what the manufacturers say.
The manufacturers of housewraps have for years promoted the fantasy that water vapor in wall assemblies only moves one way – from the inside out.
Perhaps the single most challenging BSC performance for Building America production homebuilders is that all ducts and HVAC equipment must be within the conditioned space (this means no ducts in outside walls and no ducts or air handlers in garages, vented attics or vented crawlspaces).
The simplest, most effective, and most economical way to introduce fresh air in homes with central forced air systems is to use the central fan to pull in and distribute a controlled amount of outside air.