Research Reports are technical reports written for researchers but accessible to design professionals and builders. These reports typically provide an in-depth study of a particular topic or describe the results of a research project. They are often peer reviewed and also provide support for advice given in our Building Science Digests. The most recent documents posted are at the top of the list below.
The following report is an excerpt from the 2009 Building Science Corporation Industry Team Building America Annual Report.
The software CONTAM was used to create a calibrated mulit-zone model to replicate in-field tracer gas decay measurements of a new two story, 2,600 sq. ft., single-family house in Sacramento, CA under different whole-house dilution ventilation scenarios. This report was first published in ASHRAE Transactions (17, Louisville 2009). American Society of Heating Refrigeration and Air-Conditioning Engineers, Atlanta, GA. Reprinted with permission.
A calibrated ventilation model was exercised over a range of parameters seen in new and existing housing in the United States. This report was first published in ASHRAE Transactions (17, Louisville 2009). American Society of Heating Refrigeration and Air-Conditioning Engineers, Atlanta, GA. Reprinted with permission.
This paper describes a fully instrumented large-scale mock-up completed in a southern Ontario private school to allow direct comparisons between insulated and non-insulated walls with a focus on the evaluation of freeze-thaw and corrosion risks. Climate conditions and wall temperature, relative humidity and moisture content are compared and discussed. Climate conditions (wetting and temperature) over the monitoring period were less severe than average. As a result, measured values were used to refine computer models to simulate wall performance under more severe climate conditions.
The balance between wetting, drying, and safe storage is critical to the long term performance of building enclosures. Where wetting cannot be controlled to acceptable levels, safe storage and drying become critical.
The research reported in this paper is aimed at increasing the understanding of the hygrothermal performance of interior basement insulation systems by a combination of field monitoring of four assemblies and one-dimensional computer modeling.
This paper documents the experimental methodology, details, and results and discuss how this information can be applied to modeling drained wall systems. Practical applications and research questions arising from the work are presented.
Exterior insulation and finishing systems (EIFS) are inherently defective and unfit of use as an exterior cladding system where moisture sensitive components are used without a provision for drainage or in locations and assemblies without adequate drying.
Advanced framed wall systems that use a stud spacing of 24 inches on center and eliminate the plywood or OSB sheathing from the wall and replace it with insulating sheathing is a type of enclosure assembly that has been designed to be energy efficient combined with efficient material use.
This report considers a number of promising wall systems that can meet the requirement for better thermal control. Unlike previous studies, this one considers performance in a more realistic matter, including some true three-dimensional heat flow and the relative risk of moisture damage.
This report is available from the Canadian Urethane Foam Contractors Association (http://www.cufca.ca/home_e.php). It is reproduced here for convenience. A common question encountered by SPF applicators, building designers, and code officials is the need for an additional vapor barrier or retarder. Experience by many contractors and some consultants suggest that special low permeance layers such as polyethylene are rarely needed in many types of walls. Theory indicates that closed cell foam is sufficiently vapor impermeable to control diffusion condensation and that low-density open-cell foam applications may require additional vapor diffusion control in some extreme environments. However, the need for, and type of additional vapor control layers remains unanswered to many.
This document summarizes the theory behind thermal insulation and building system heat flow control metrics and presents a literature review of selected research into this area.
This report is an excerpt from the 2008 Building America Annual Report. Following the almost complete destruction of Greensburg, Kansas by a tornado in May, 2007, Building Science Corporation (BSC) was contracted to provide example house plans, support for
the reconstruction of energy efficient houses and training for builders and trades. This report describes the planning, execution, and results of BSC’s builder training program in Greensburg.
This report is an excerpt from the 2008 Building America Annual Report. Following the almost complete destruction of Greensburg, Kansas by a tornado in May, 2007, Building Science Corporation (BSC) was contracted to provide example house plans, support for the reconstruction of energy efficient houses and training for builders and trades. This report describes the results of BSC’s work to construct more than 20 energy efficient, affordable, durable houses in Greensburg, Kansas.
The following report is an excerpt from the 2008 Building Science Corporation Industry Team Building America Annual Report. This summary includes whole-house performance and systems engineering, construction support, source energy savings and quality control requirements and integration.
Uniform distribution of outside air is one way to ensure that residential dilution ventilation systems will provide a known amount of fresh air to all rooms regardless of house geometry and occupant behavior.
In order for dilution ventilation systems to provide predictable results independent of the geometry of individual homes, outside air must be uniformly distributed throughout the house
Brick is a reservoir cladding, meaning that it absorbs and stores water (rain) when it becomes wet. In some homes, with brick veneer cladding systems, mold contamination has occurred within exterior wall cavities. In some homes, wood decay at bottom plates has also occurred.
This paper discusses Building America whole house systems research within the broad effort to reduce or eliminate the environmental impact of building and provides specific recommendations for future Building America research based on Building Science Corporation’s experience with several recent projects involving green home building programs.
Unvented roof systems can be safely used in many different climates. In cold climates, insulating sheathing must be added exterior to the roof sheathing to prevent condensation on the underside of the roof sheathing.