Published Articles are a selected set of articles written by BSC personnel and published in professional and trade magazines that address building science topics. For example, our work has appeared in Fine Homebuilding, Home Energy, ASHRAE’s High Performance Buildings, The Journal of Building Enclosure Design and The Journal of Building Physics. We thank these publications for their gracious permission to republish.
We are passionate about building science and welcome new opportunities to share information. If your publication needs content about energy efficiency, durability, or other aspects of high-performance building, please contact us at info@buildingscience.com.
One-third of the energy you buy probably leaks through holes in your house. Reprinted with permission from Fine Homebuilding, pages 45-49, October/November 2012.
What we learned from updating a 16-year-old deep-energy retrofit. Reprinted with permission from Fine Homebuilding, February/March 2012, pages 55-59.
Windows and curtainwalls are ubiquitous building enclosure components. Like all parts of the building enclosure, they have to meet the fundamental functional requirements of support, control and finish (Straube & Burnett, 2005). Reprinted with permission from Journal of Building Enclosure Design, Winter 2010, pages 12 -15.
Electrically commutated motors (ECM) in air-handler fans promise improved efficiency. But does improved technology necessarily mean efficient HVAC systems? This article was first published in Home Energy, May/June 2010. Reprinted with permission.
Adhered veneers, in which masonry units are directly attached to a substrate via mortar and ties without a drainage or ventilation gap, have become a very popular finish in residential and light commercial construction. Reprinted with permission from Journal of Building Enclosure Design, Summer 2009, pages 31 - 35.
Today’s houses make it easier for mold to find the food and water it needs to thrive. The cure is a quick cleanup and smarter choices in materials. Reprinted with permission from Fine Homebuilding, December 2006/January 2007, pages 70-75.
By creating a path for air to move, structural vents are supposed to prevent the buildup of moisture in an attic. This article was first published in Builder Magazine, January 2006.
Smarter strategies can save money, speed construction, improve energy efficiency, and cut down on jobsite waste. Reprinted with permission from Fine Homebuilding, October/November 2005, pages 50-55.
This article reports on field experience of unvented cathedralized (UC) attics in several environments in the United States. Traditionally, in some regions of the country, because of high water tables or the risk of flash flooding and lower cost, slab on grade construction is a preferred mode of construction. Mechanical equipment for air conditioning and distribution ducts are usually located in the attic spaces to conserve space. Conventional construction involves providing insulation on the floor of the attic and venting the attic space to the outside. The loss in efficiency in operation of the equipment and through duct leakage is no longer sustainable. Insulating the attic roof itself and blocking of ventilation to the outside transfers the air and thermal energy controls from the boundary with the living space to the plane of the roof. The air distribution systems now fall within conditioned space, which increases their efficiency, durability, and maintainability. This article was first published in the Journal of Building Physics, Vol. 29, October 2005.
Top ten blunders that rot your house, waste your money, and make you sick. Reprinted with permission from Fine Homebuilding Magazine, April/May 2004, pages 52-56.
Show water to the exit with a well-detailed drainage plane and flashings. Rerpinted from Journal of Light Construction, March 2003.
Outdoor air is added to a building via a controlled ventilation system. What isn't controlled is the air change created by wind effects, stack effects and pressure effects caused by the operation of the HVAC system. The following article was published in ASHRAE Journal, April, 2002, pages 18-21. Reprinted with permission.
How water gets into a structure, why it doesn’t leave, and how these architectural flaws become HVAC headaches. This two-part article was first published in HPAC Engineering, December 2001 and January 2002.
Here we explore issues unique to Veterans Era Housing and present three cases where moisture problems were successfully addressed. Originally published in Home Energy November/December 2001, pages 33-37.
Multifamily public and low-income housing have particular problems when it comes to moisture and air pollutants. In this first of a two-part series, we look at one particular type of multifamily construction: midrise housing. Originally published in Home Energy September/October 2001, pages 24-28.