Search Document Types   →   Building America Reports
BA 

Building America Reports

21-40 of 88 Items
Left arrow 1 2 3 4 5 Left arrow
Show All
BA

BA-1312: Application of Spray Foam Insulation Under Plywood and OSB Roof Sheathing

By Aaron Grin, Jonathan Smegal and Joseph Lstiburek
Download.pdf  10.3 MB

BA

BA-1311: Evaluation of Two CEDA Weatherization Pilot Implementations of an Exterior Insulation and Over-Clad Retrofit Strategy for Residential Masonry Buildings in Chicago

By Ken Neuhauser
Download.pdf  7.2 MB

BA

BA-1310: Supplemental Dehumidification in Warm-Humid Climates

By Armin Rudd
Download.pdf  2.5 MB

BA

BA-1309: Ventilation System Effectiveness and Tested Indoor Air Quality Impacts

By Armin Rudd and Daniel Bergey
Download.pdf  2.8 MB

BA

BA-1308: Moisture Control for Dense-Packed Roof Assemblies in Cold Climates: Final Measure Guideline

By Chris Schumacher and Robert Lepage
Download.pdf  2.2 MB

BA

BA-0505: Residential Dehumidification Systems Research for Hot-Humid Climates

By Armin Rudd, Joseph Lstiburek, Kohta Ueno
Download.pdf  2.2 MB

BA

BA-1307: Interior Insulation of Mass Masonry Walls: Joist Monitoring, Material Test Optimization, Salt Effects

By Kohta Ueno, Randy Van Straaten, Chris Schumacher
Download.pdf  6.9 MB

BA

BA-1303: Transformations, Inc.: Partnering to Build Net-Zero Energy Houses in Massachusetts

By Ueno/Wytrykowska/Bergey
Download.pdf  6.0 MB

BA

BA-1302: Retrofit of a Multi-family Mass Masonry Building in New England

By Ueno/Kerrigan/Wytrykowska/Van Straaten
Download.pdf  15.5 MB

BA

BA-1301: Guidance on Taped Insulating Sheathing Drainage Planes—Final Report

By Aaron Grin and Joseph Lstiburek
Download.pdf  2.0 MB

BA

BA-1209: Multifamily Ventilation Retrofit Strategies

By Kohta Ueno, Joseph Lstiburek, and Daniel Bergey
Download.pdf  6.6 MB

BA

BA-1208: Performance Evaluation of a Hot-Humid Climate Community

By Rosie Osser and Phil Kerrigan
Download.pdf  2.5 MB

BA

BA-1203: Measure Guideline—Wood Window Repair, Rehabilitation, and Replacement

By Peter Baker
Download.pdf  11.3 MB

BA

BA-1202: Byggmeister Test Home—Cold Climate Multifamily Masonry Building Condition Assessment and Retrofit Analysis

By Honorata Wytrykowska, Kohta Ueno, Randy Van Straaten
Download.pdf  7.4 MB

BA

BA-1206: Measure Guideline–Combination Forced-Air Space and Tankless Domestic Hot Water Heating Systems

By Armin Rudd
Download.pdf  4.1 MB

BA

BA-1205: Attic or Roof? An Evaluation of Two Advanced Weatherization Packages

By Ken Neuhauser
Download.pdf  3.7 MB

BA

BA-1204: External Insulation of Masonry Walls and Wood Framed Walls

By Peter Baker
Download.pdf  12.4 MB

BA

BA-1210: Moisture and Structural Analysis for High Performance Hybrid Wall Assemblies

By Aaron Grin and Joseph Lstiburek
Download.pdf  3.5 MB

BA

BA-1108: Hybrid Foundation Insulation Retrofits: Measure Guidelines

By Kohta Ueno and Joseph Lstiburek
Download.pdf  4.5 MB

BA

BA-1107: Final Retrofit Pilot Community Evaluation Report

By Rosie Osser, Ken Neuhauser and Kohta Ueno
Download.pdf  4.3 MB

21-40 of 88 Items
Left arrow 1 2 3 4 5 Left arrow
Show All