Air Sealing / Air Drywall Approach Details

A tight building enclosure is necessary to control the movement of air in and out of building assemblies. This is important for energy conservation, thermal comfort and building durability. Moisture laden air moving into wall or roof assemblies (particularly from the exterior during cooling in hot-humid climates or from the interior during heating in cold climates) may lead to condensation and result in deterioration of moisture sensitive materials. An air flow retarder can be installed on the interior or the exterior side of the envelope or on both sides. For more detailed discussion on air flow retarders, click here.

Controlling air movement through the building enclosure requires sealing both the "big" holes and the "little" holes. The big holes occur behind bath tubs and showers on exterior walls, behind fireplaces, and where soffits or utility walls (double wall with chase) meet exterior walls or ceilings. Recessed lights collectively can be a really big hole in the ceiling assembly. These big holes are responsible for wasted energy (high utility bills), frozen pipes and condensation that can cause mold and wood decay. These big holes are easy to seal during the framing stage but only when someone has the responsibility for making sure it gets done.

The small holes occur between framing members (such as band joist to sill plate), around electrical boxes and where plumbing or wiring penetrate the envelope. The Air Drywall Approach uses the gypsum board to provide an interior air flow retarder. The gypsum board is sealed to the framing members at the perimeter of exterior walls and around penetrations such as doors, windows, and attic hatches. The gypsum board is also sealed to electrical boxes on exterior walls. Air cannot move through the gypsum board and the taped corners. Details of air sealing and the ADA are illustrated below. Photographs of many of these details are also shown in the file of photos attached to each Designs that Work climate design.

Air Sealing Details

Click on detail for expanded view.
Exterior Air Flow Retarder using Stucco figure_3.01.gif (10337 bytes) Interior Air Flow Retarder using Drywall & Framing figure_3.02.gif (9085 bytes)
Interior Air Flow Retarder Using Poly

Note: Only recommended for very cold climates.

 figure_3.03.gif (9349 bytes) Exterior Air Flow Retarder using Exterior Sheathing figure_3.04.gif (8405 bytes)
Exterior AFR using Building Paper or Housewrap figure_3.05.gif (12184 bytes) Intersection of Interior Partition Wall & Exterior Wall figure_3.06.gif (5672 bytes)
Intersection of Interior Wall and Insulated Ceiling figure_3.07.gif (5090 bytes) Intersection of Floor Joists and Exterior Wall figure_3.08.gif (5074 bytes)
Intersection Interior Partitions figure_3.09.gif (4747 bytes) Window Jamb with Wood Trim figure_3.10.gif (3636 bytes)
Window Jamb with Drywall Returns figure_3.11.gif (3448 bytes) Rim Joist / Band Joist Closure figure_8.20.gif (7417 bytes)
Floor Truss Rim Closure figure_8.21.gif (7321 bytes) Set-back Rim Joist figure_8.22.gif (4289 bytes)
Band Brace / Floor Truss Closure figure_8.23.gif (6498 bytes) Cantilevered Floors figure_8.24.gif (12152 bytes)
Alternative Cantilevered Floors figure_8.25.gif (8443 bytes) Floor Over Garage figure_8.27.gif (8124 bytes)
Shed Roof figure_8.28.gif (9584 bytes) Set-back Roof figure_8.29.gif (8677 bytes)
Tub Framing figure_8.30.gif (13582 bytes) Tub Framing - Plan figure_8.31.gif (8769 bytes)
Tub Framing - Interior Elevation figure_8.32.gif (6607 bytes) Fireplace Section figure_8.33.gif (18308 bytes)
Fireplace - Plan View figure_8.34.gif (16021 bytes) Flue Closure figure_8.35.gif (6940 bytes)
Alternative Flue Closure figure_8.36.gif (10419 bytes) Interior Soffit figure_8.37.gif (3461 bytes)
Interior Soffit Constructed After Gypsum Board Installed figure_8.38.gif (5324 bytes) Dropped Ceiling figure_8.39.gif (4472 bytes)
Interior soffit Constructed Before Gypsum Board Installed figure_8.40.gif (9817 bytes) Utility Chase figure_8.41.gif (10329 bytes)
Split Level figure_8.42.gif (7415 bytes) Attic Access figure_8.44.gif (5485 bytes)
Stairs at Exterior wall or Garage Wall figure_8.45.gif (13737 bytes)  