Moisture is one of the most important agents leading to building enclosure deterioration. Understanding and predicting moisture movement within and through the enclosure is therefore of fundamental importance to predicting and improving building enclosure performance, particularly durability. Since driving rain deposition on walls and roofs is quantitatively the largest single source of moisture for most walls and roofs, it is no surprise that controlling rain penetration is one of the most important parts of a successful moisture control strategy. In fact, failure to control rain is likely the oldest and most common serious building enclosure performance problem. Commentators as long as Vitruvius (70 BC) bemoaned the challenges of controlling rain penetration.
This document will consider rain control from a general to a specific level. The following sections will cover: basic moisture control principles that should be employed in the design of above-grade building enclosures; driving rain as a moisture load on walls; a classification system of the various rain control strategies available for walls; and finally, good design practises for walls. The rain control of roofs will be covered in more detail in another BSD.
-
BSD-105: Understanding Drainage Planes
by
Joseph Lstiburek
—
last modified
2008/10/14
-
Controlling rain is the single most important factor in the design and construction of durable buildings and in the control of mold.
Drainage planes are used in the design and construction of building enclosures to control rain.
All exterior claddings pass some rainwater. Siding leaks, brick leaks, stucco leaks, stone leaks, etc. As such, some control of this penetrating rainwater is required. In most walls, this penetrating rainwater is controlled by the drainage plane that directs the penetrating water downwards and outwards.
-
BSD-106: Understanding Vapor Barriers
by
Joseph Lstiburek
—
last modified
2008/10/17
-
The function of a vapor barrier is to retard the migration of water vapor. Where it is located in an assembly and its permeability is a function of climate, the characteristics of the materials that comprise the assembly and the interior conditions. Vapor barriers are not typically intended to retard the migration of air. That is the function of air barriers.
-
BSD-109: Pressures in Buildings
by
Joseph Lstiburek
—
last modified
2008/08/20
-
Air flow in buildings is one of the major factors that governs the interaction of the building structure with the mechanical system, climate and occupants. If the air flow at any point within a building or building assembly can be determined or predicted, the temperature and moisture (hygrothermal or pyschometric) conditions can also be determined or predicted. If the hygrothermal conditions of the building or building assembly are known, the performance of materials can also be determined or predicted
-
BSD-111: Flood and Hurricane Resistant Buildings
by
Joseph Lstiburek
—
last modified
2008/08/21
-
We learn our lessons from disaster. Hurricane Andrew taught us about wind. Hurricanes Charley, Frances and Jeanne taught us about rain. The Red River of the North Basin taught us about floods. Hurricane Katrina had it all: wind, rain and flood.
That we will rebuild, and rebuild in the same place, is not in doubt. This is what we do – for better or worse.
If we are to rebuild and if we are to rebuild in the same place how should we rebuild?
-
BSD-114: Interior Insulation Retrofits of Load-Bearing Masonry Walls In Cold Climates
by
John Straube
—
last modified
2008/09/09
-
This digest reviews the moisture control principles that must be followed for a successful insulated retrofit of a solid load-bearing masonry wall. Two possible apporaches to retrofitting such walls are presented and compared.
-
BSI-001: The Perfect Wall
by
Joseph Lstiburek
—
last modified
2008/09/09
-
An edited version of this Insight first appeared in the ASHRAE Journal.
The perfect wall is an environmental separator – it has to keep the outside out and the inside in. In order to do this the wall assembly has to control rain, air, vapor and heat.
|