You are here: Home Design Guidance Building science and design Below-grade enclosure Below-grade enclosure Documents
 

Below-grade enclosure Documents

Up one level
BSD-013: Rain Control in Buildings by John Straube — last modified 2008/09/09
Moisture is one of the most important agents leading to building enclosure deterioration. Understanding and predicting moisture movement within and through the enclosure is therefore of fundamental importance to predicting and improving building enclosure performance, particularly durability. Since driving rain deposition on walls and roofs is quantitatively the largest single source of moisture for most walls and roofs, it is no surprise that controlling rain penetration is one of the most important parts of a successful moisture control strategy. In fact, failure to control rain is likely the oldest and most common serious building enclosure performance problem. Commentators as long as Vitruvius (70 BC) bemoaned the challenges of controlling rain penetration. This document will consider rain control from a general to a specific level. The following sections will cover: basic moisture control principles that should be employed in the design of above-grade building enclosures; driving rain as a moisture load on walls; a classification system of the various rain control strategies available for walls; and finally, good design practises for walls. The rain control of roofs will be covered in more detail in another BSD.
BSD-103: Understanding Basements by Joseph Lstiburek — last modified 2008/10/20
Buildings used to be constructed over cellars. Cellars were dank, dark places where coal was stored. People never intended to live in cellars. Now we have things called basements that have pool tables, media centers and play rooms. Cellars were easy to construct – rubble, stone, bricks and sometimes block. If they got wet or were damp so what? Basements are different. They are not easy to construct if we intend to live in them. They need to be dry, comfortable and keep contaminants out. Over the last 50 years there has been a notable expansion of living space. The useful conditioned space of building enclosures is expanding to the outer edge of the building skin (Figure 1). Attics, crawlspaces, garages and basements are valuable real estate that are being used to live in or used for storage or places to locate mechanical systems. Basements are viewed by many as cheap space that can easily be incorporated into a home. Keeping basements dry, comfortable and contaminant free is proving to be anything but simple.
BSI-009: New Light In Crawlspaces by Joseph Lstiburek — last modified 2008/10/16
An edited version of this Insight first appeared in the ASHRAE Journal. Think of the good old days—the Civil War, WWI, the Great Depression, WWII—crawlspaces were uninsulated. They were ventilated and they didn’t have ground covers—and they didn’t have problems. Why?