See the table below for a quick reference to additional building
profiles in different hygro-thermal regions. A
Building Materials Property Table*
(populated with technical and performance specifications from product
manufacturers and building research members of the Building Science
Consortium) can also be used for reference.
|
Climate/Building Profile |
# stories |
Wall Type |
Foundation |
Wall Cladding |
Roof |
Roof Cladding |
|
Very Cold |
|
Aspen |
2 |
Stick-
framed |
Conditioned crawlspace |
Fiber cement battened
panels |
Unvented cathedral |
Standing seam metal |
|
Concord |
1 |
Stick-
framed |
Full basement |
Wood siding |
Vented unconditioned attic |
Asphalt shingle |
|
Cold |
|
Beacon Hill |
1.5 |
Stick-
framed |
Full basement |
Brick veneer |
Unvented cathedral |
Slate roof |
|
Boston |
2 |
Stick-
framed |
Full basement |
Fibercement panels and
battens |
Conditioned attic |
Asphalt shingle |
|
Chicago |
2 |
Stick-
framed |
Full
basement/
cast concrete |
Vinyl siding |
Vented
unconditioned attic |
Asphalt
shingle |
|
Denver |
2 |
Stick-
framed |
Full basement
w/ sub-crawl |
Brick
veneer/wood siding |
Vented
unconditioned attic |
Asphalt
shingle |
|
Minneapolis |
1.5 |
Stick-
framed |
Slab-on-grade |
Stucco |
Vented
cathedral |
Asphalt
shingle |
|
Vineyard |
2 |
Stick-
framed |
Full basement |
Cedar shingle siding |
Unvented cathedral |
Cedar shingle |
|
Mixed-Humid |
|
Atlanta |
2 |
Stick-
framed |
Slab-on-grade |
Fibercement
siding |
Vented
unconditioned attic |
Asphalt
shingle |
|
Charlotte |
2 |
Stick-
framed |
Conditioned
crawl/ block wall |
Brick veneer |
Vented
unconditioned attic |
Asphalt
shingle |
|
Louisville |
1 |
Stick-
framed |
Full
basement/
cast concrete |
Vinyl siding |
Vented
cathedral |
Asphalt
shingle |
|
Hot-Dry/Mixed-Dry |
|
Albuquerque |
1 |
Stick-
framed |
Slab-on-grade |
Stucco |
Vented
unconditioned attic |
Asphalt
shingle |
|
Sacramento |
2 |
Stick-
framed |
Post-tensioned slab-on-grade |
Fibercement
siding |
Vented
unconditioned attic |
Tile |
|
Tucson |
1 |
Stick-
framed |
Slab-on-grade |
Stucco |
None |
Low-slope
membrane |
|
Hot-Humid |
|
Houston |
2 |
Stick-
framed |
Slab-on-grade |
Brick/
Fibercement |
Conditioned
attic |
Asphalt
shingle |
|
Maitland |
2 |
Block/
stick frame |
Block stem
wall & slab |
Stucco |
Conditioned
attic |
Tile |
|
Orlando |
2 |
SIPS |
Block stem wall with slab |
Cement board siding / brick veneer |
Conditioned
attic |
Metal roof |
|
Montgomery |
1 |
Stick-
framed |
Conditioned
crawl/ cast concrete wall |
Vinyl or
aluminum lap siding |
Vented
unconditioned attic |
Standing seam
metal |