A list of all published glossary terms on this site.
Wind Washing by John Straube — last modified 2006/06/11
The effect of wind-driven air movement through air permeable insulation reduces its insulating value . . .
Water Resistant Barrier by John Straube — last modified 2006/06/11
A sheet, spray- or trowel-applied membrane or material layer . . .
Sourced Drained by John Straube — last modified 2006/06/11
Another term for a face sealed system . . .
Sheathing Membrane by John Straube — last modified 2006/06/11
A generic term for a membrane layer that prevents the resists the passage of liquid water and possibly air and vapor . . .
Sealant by John Straube — last modified 2006/06/11
A flexible, polymer-based elastomeric material . . .
Semi-rigid Insulation by John Straube — last modified 2006/06/11
Board material which provides thermal resistance comprised of mineral fibers . . .
Rigid Insulation by John Straube — last modified 2006/06/11
Rigid board material which provides thermal resistance . . .
Radiation by John Straube — last modified 2006/06/11
A form of energy in electro-magnetic radiation . . .
Psychrometrics by John Straube — last modified 2006/06/11
The study of air and its energy and water vapour contents.
Joints by John Straube — last modified 2006/06/11
An interface between elements . . .
Flashing by John Straube — last modified 2006/06/11
A waterproof material used to redirect or shed drained water, or occasionally to act as a capillary break . . .
Expansion Joint by John Straube — last modified 2006/06/11
A structural separation between building elements . . .
Building Enclosure by Joseph W. Lstiburek — last modified 2007/05/22
A building enclosure is the component (typically comprised . . .
Mold by Joseph W. Lstiburek — last modified 2006/12/05
Mold is one type of fungus which is different from plants, animals and . . .
EIFS (external insulation finishing system) by Joseph W. Lstiburek — last modified 2006/12/05
A combination of insulation and stucco system cladding for . . .
Spectrally Selective Glazing by Joseph W. Lstiburek — last modified 2006/12/05
These types of window systems reduce solar gain while still providing daylighting . . .
Hygroscopic by Building Science Corporation — last modified 2006/12/05
Materials that change their permeability characteristics as relative humidity . . .
Hydrophobic by Joseph W. Lstiburek — last modified 2006/12/05
Materials that do not change their permeability as a function of relative . . .
Commissioning by Joseph W. Lstiburek — last modified 2006/12/05
Prior to occupancy, testing and inspections should note any problems and they . . .
Vapor Permeance Classes by Joseph W. Lstiburek — last modified 2007/05/21
Test procedure for determining vapor permeance class is...